A new two-tier strength assessment approach to the diagnosis of weakness in intensive care: an observational study

نویسندگان

  • Selina M Parry
  • Sue Berney
  • Catherine L Granger
  • Danielle L Dunlop
  • Laura Murphy
  • Doa El-Ansary
  • René Koopman
  • Linda Denehy
چکیده

INTRODUCTION Intensive care unit-acquired weakness (ICU-AW) is a significant problem. There is currently widespread variability in the methods used for manual muscle testing and handgrip dynamometry (HGD) to diagnose ICU-AW. This study was conducted in two parts. The aims of this study were: to determine the inter-rater reliability and agreement of manual muscle strength testing using both isometric and through-range techniques using the Medical Research Council sum score and a new four-point scale, and to examine the validity of HGD and determine a cutoff score for the diagnosis of ICU-AW for the new four-point scale. METHODS Part one involved evaluation of muscle strength by two physical therapists in 29 patients ventilated >48 hours. Manual strength testing was performed by both physical therapists using two techniques: isometric and through range; and two scoring systems: traditional six-point Medical Research Council scale and a new collapsed four-point scale. Part two involved assessment of handgrip strength conducted on 60 patients. A cutoff score for ICU-AW was identified for the new four-point scoring system. RESULTS The incidence of ICU-AW was 42% (n = 25/60) in this study (based on HGD). In part one the highest reliability and agreement was observed for the isometric technique using the four-point scale (intraclass correlation coefficient = 0.90: kappa = 0.72 respectively). Differences existed between isometric and through-range scores (mean difference = 1.76 points, P = 0.005). In part two, HGD had a sensitivity of 0.88 and specificity of 0.80 for diagnosing ICU-AW. A cutoff score of 24 out of 36 points was identified for the four-point scale. CONCLUSIONS The isometric technique is recommended with reporting on a collapsed four-point scale. Because HGD is easy to perform and sensitive, we recommend a new two-tier approach to diagnosing ICU-AW that first tests handgrip strength with follow-up strength assessment using the isometric technique for muscle strength testing if handgrip strength falls below cutoff scores. Whilst our results for the four-point scale are encouraging, further research is required to confirm the findings of this study and determine the validity of the four-point scoring system and cutoff score developed of less than 24 out of 36 before recommending adoption into clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Prediction of Intensive Care Unit–Acquired Weakness Using Easily Available Parameters: A Prospective Observational Study

INTRODUCTION An early diagnosis of Intensive Care Unit-acquired weakness (ICU-AW) using muscle strength assessment is not possible in most critically ill patients. We hypothesized that development of ICU-AW can be predicted reliably two days after ICU admission, using patient characteristics, early available clinical parameters, laboratory results and use of medication as parameters. METHODS ...

متن کامل

Effect of Classical Music on Physiological Characteristics and Observational and Behavioral Measures of Pain in Unconscious Patients Admitted to Intensive Care Units

Objective: Assessment and management of pain in patients under artificial respiration and hospitalized in Intensive Care Units (ICUs) are difficult, and is less considered by physicians and nurses. This study aims to determine the effect of classical music on physiological characteristics, and observational and behavioral measures of pain in unconscious patients admitted to ICUs. Methods: This...

متن کامل

Neurofilaments as a plasma biomarker for ICU-acquired weakness: an observational pilot study

INTRODUCTION Early diagnosis of intensive care unit - acquired weakness (ICU-AW) using the current reference standard, that is, assessment of muscle strength, is often hampered due to impaired consciousness. Biological markers could solve this problem but have been scarcely investigated. We hypothesized that plasma levels of neurofilaments are elevated in ICU-AW and can diagnose ICU-AW before m...

متن کامل

An Approach to Management of Health Care and Medical Diagnosis Using of a Hybrid Disease Diagnosis System

Introduction: In order to simplify the information exchange within the medical diagnosis process, a collaborative software agent’s framework is presented. The purpose of the framework is to allow the automated information exchange between different medicine specialists. Methods: This study presented architecture of a hybrid disease diagnosis system. The architecture employed a learning...

متن کامل

Two-tier Supplier Base Efficiency Evaluation Via Network DEA: A Game Theory Approach

In today's competitive markets, firms try to reduce their supply cost by selecting efficient suppliers using different techniques. Several methods can be applied to evaluate the efficiency of supplier base. This paper develops generalized network data envelopment analysis models to examine the efficiency of two-tier supplier bases under cooperative and non-cooperative strategies where each tier...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015