Potentiometric determination of bromate using an Fe(III)-Fe(II) potential buffer by circulatory flow-injection analysis.
نویسندگان
چکیده
A method for the potentiometric determination of bromate by circulatory flow injection analysis (CFIA) is described. The procedure involves the use of an Fe(III)-Fe(II) potential buffer solution, which is recycled via a reservoir. The analytical method is based on a linear relationship between the concentration of bromate and a very transient potential change in the electrode potential due to the generation of intermediate bromine during the reaction of bromate with the Fe(III)-Fe(II) potential buffer solution, which also contains NaBr, (NH4)6Mo7O24 and H2SO4. An aliquot (5 microl) of a bromate sample solution was injected into the stream of the potential buffer solution, 100 ml of which was circulated at a flow rate of 1 ml/min; the potential buffer solution stream was then returned to the reservoir after passing through a flow-through redox electrode detector. A potential change due to the reaction of the injected sample with the potential buffer in a reaction coil was measured with the detector in the form of a peak signal. The effects of the bromide, sulfuric acid and Fe(III)-Fe(II) concentrations in the potential buffer, and length of the reaction coil on the peak heights were examined in order to optimize the proposed CFIA method. The analytical sensitivities to bromate were 5.6 mV/microM for 1 x 10(-2) M and 30.9 mV/microM for 1 x 10(-3) M in the concentration of Fe(III)-Fe(II) in a potential buffer solution containing 0.35 M NaBr, 0.2% (NH4)6Mo7O24 and 1 M H2SO4. The detection limit of bromate obtained by a 1 x 10(-3) M Fe(III)-Fe(II) potential buffer solution was 0.02 microM (2.5 ppb). The numbers of repetitive determinations in which the relative sensitivities within 5% were regarded as being tolerated were ca. 4000 and 2000 for the use of only 100 ml of 1 x 10(-2) M and 1 x 10(-3) M Fe(III)-Fe(II) potential buffer solution, respectively.
منابع مشابه
Rapid and Automated Analytical Methods for Redox Species Based on Potentiometric Flow Injection Analysis Using Potential Buffers
Two analytical methods, which prove the utility of a potentiometric flow injection technique for determining various redox species, based on the use of some redox potential buffers, are reviewed. The first is a potentiometric flow injection method in which a redox couple such as Fe(III)-Fe(II), Fe(CN)(6) (3-)-Fe(CN)(CN)(6) (4-), and bromide-bromine and a redox electrode or a combined platinum-b...
متن کاملFlow injection potentiometric determination of Fe ( III ) using a fluoride - selective electrode as detector *
Flow injection analysis (FIA) system incorporating a fluoride ion-selective electrode (FISE) as detector is described. Laboratory-built cascade flow cell equipped with FISE and reference electrode is used for flow injection potentiometric determination of Fe(III) based on monitoring of the formation of FeF2 in acid solution. Under optimized flow conditions (4.0 mL min–1, 300 μL samples, 10–5 mo...
متن کاملA Simple Flow Injection Spectrophotometric Determination of Iron Using Nitroso-R salt as complexing agent
Flow injection (FI) spectrophotometric method for iron (III) determination using Disodium-1-nitroso-2-naphthol-3,6disulphonate (nitroso-R salt) is performed. It is based on the measurement of Fe(III)-nitroso-R salt complex at 720 nm formed by the reaction between Fe(III) and nitroso-R salt in an acetate buffer solution pH 5. The FI parameters that affect the signal response have been optimized ...
متن کاملApplication of a New Macrocyclic -PVC Electrode to Potentiometric Studies of Fe(III) Ion
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
متن کاملRapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
A method for speciation and determination of low levels of dissolved iron in rainwater was established by coupling reverse flow injection analysis with a 2-m liquid waveguide capillary cell and spectrophotometric detection. Ferrozine solution was injected into a sample stream to form an Fe(II)-ferrozine complex with Fe(II), and the absorbance of this complex was detected at both 562 nm and 625 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2004