Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT.

نویسندگان

  • L Romano
  • L Grazioli
  • L Bonomo
  • J-R Xu
  • K-M Chen
  • R Dore
  • A Vanzulli
  • C Catalano
چکیده

The purpose of this study was to compare iomeprol-400 and iodixanol-320 for contrast enhancement and safety in patients undergoing liver multidetector CT (MDCT). 183 patients undergoing MDCT received equi-iodine (40 gI) iomeprol-400 (n = 91) or iodixanol-320 (n = 92) IV at 4 ml s(-1). Two off-site, independent, blinded readers determined the contrast density (in Hounsfield units (HUs)) in the abdominal aorta, inferior vena cava, portal vein and liver parenchyma during the arterial and portal phases. The mean contrast densities achieved were compared and 95% confidence intervals (CIs) estimated. Heart rate was measured at baseline and at post-dose peak, and a full safety assessment was performed. Study group demographics were comparable. Iomeprol-400 produced significantly greater enhancement of the aorta during the arterial phase (Reader 1: 337.3 HU vs 294.9 HU, 95% CI of difference (19.4, 65.5), p = 0.0004; Reader 2: 325.7 HU vs 295.3 HU, 95% CI of difference (6.6, 54.3), p = 0.01) and greater enhancement of the liver parenchyma during the portal venous phase (Reader 1: 115.1 H vs 108.6 HU, 95% CI of difference (0.27, 12.7), p = 0.04; Reader 2: 115.2 H vs 109.3 HU, 95% CI of difference (-0.1, 11.8), p = 0.05). Similar enhancement of the inferior vena cava and portal vein was noted. Comparably negligible increases in the mean heart rate were observed. Adverse events occurred in 1/91 (1.1%) subjects after iomeprol-400 and 4/92 (4.3%) subjects after iodixanol-320. In conclusion, iomeprol-400 produces greater arterial and portal phase enhancement and has a similarly negligible impact on heart rate and safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast media induced nephropathy: CONTRAST There is an ongoing controversy on the impact of iso- osmolar contrast agents on contrast media induced nephropathy (CIN). The COntrast Media and Neph- roToxicity Following Coronary Revascularization by AngioplaSTy

There is an ongoing controversy on the impact of isoosmolar contrast agents on contrast media induced nephropathy (CIN). The COntrast Media and NephroToxicity Following Coronary Revascularization by AngioplaSTy (CONTRAST) randomized 324 patients with impaired renal function undergoing PCI to receive either the iso-osmolar contrast medium iodixanol 320 (Visipaque ) or the low-osmolar contrast me...

متن کامل

Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400

BACKGROUND Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. PURPOSE To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. MATERIAL AND METHODS Patients were prospectively enrolled and were ran...

متن کامل

Choice of contrast medium in patients with impaired renal function undergoing percutaneous coronary intervention.

BACKGROUND No clinical trial has yet focused on contrast-mediated nephrotoxicity in patients with chronic renal failure exclusively undergoing percutaneous coronary intervention (PCI). Therefore, the aim of this study was to compare the effect of contemporary contrast media on nephrotoxicity in this high-risk patient population. METHODS AND RESULTS This prospective, randomized, double-blind, ...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Safety enhancement in adult body computed tomography scanning: comparison of iodixanol versus iohexol.

BACKGROUND The aim of this study was to compare the safety and intra-individual contrast enhancement of low-osmolar monomeric iohexol and the iso-osmolar dimeric iodixanol in body computed tomography (CT) scanning. METHODS In this single center, double-blind, prospective study, a total of 2000 consecutive patients undergoing adult body CT scanning were prospectively enrolled, with 1000 patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 82 975  شماره 

صفحات  -

تاریخ انتشار 2009