A New Method of Measuring the Amount of Soft Tissue in Pulmonary Ground-Glass Opacity Nodules: a Phantom Study

نویسندگان

  • Kyung Won Lee
  • Jung-Gi Im
  • Tae Jung Kim
  • Chang Min Dae
چکیده

OBJECTIVE To devise a new method to measure the amount of soft tissue in pulmonary ground-glass opacity nodules, and to compare the use of this method with a previous volumetric measurement method by use of a phantom study. MATERIALS AND METHODS Phantom nodules were prepared with material from fixed normal swine lung. Forty nodules, each with a diameter of 10 mm, were made with a variable mean attenuation. The reference-standard amount of soft tissue in the nodules was obtained by dividing the weight by the specific gravity. The imaging data on the phantom nodules were acquired with the use of a 16-channel multidetector CT scanner. The CT-measured amount of soft tissue of the nodules was calculated as follows: soft tissue amount = volume x (1 + mean attenuation value / 1,000). The relative percentage error (RPE) between the CT-measured amount of the soft tissue and the reference-standard amount of the soft tissue was also measured. The RPEs determined with use of the new method were compared with the RPEs determined with the current volumetric measurement method by the use of the paired t test. RESULTS The CT-measured amount of soft tissue showed a strong correlation with the reference-standard amount of soft tissue (R(2) = 0.996, p < 0.01). The mean RPE of the CT-measured amount of soft tissue in the nodules was -7.79 +/- 1.88%. The mean RPE of the CT-measured volume was 114.78 +/- 51.02%, which was significantly greater than the RPE of the CT-measured amount of soft tissue (p < 0.01). CONCLUSION The amount of soft tissue measured by the use of CT reflects the reference-standard amount of soft tissue in the ground-glass opacity nodules much more accurately than does the use of the CT-measured volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT.

OBJECTIVE The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity. MATERIALS AND METHODS To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, ...

متن کامل

Evaluation of pure ground glass pulmonary nodule: a case report

A pulmonary nodule is a single, nearly spherical, well-circumscribed pulmonary opacity up to 30 mm in diameter and surrounded by aerated lung tissue. In radiographs, pulmonary nodules may appear as solid, completely obscuring the lung parenchyma, or as subsolid, not completely obscuring adjacent tissues. A subsolid pulmonary nodule may be further subclassified as a pure ground glass nodule (pGG...

متن کامل

Solitary ground-glass opacity nodules of stage IA pulmonary adenocarcinoma: combination of 18F-FDG PET/CT and high-resolution computed tomography features to predict invasive adenocarcinoma

To investigate the performance of combined 18F-FDG Positron Emission Tomography/Computed Tomography with high-resolution CT for differentiating invasive adenocarcinoma from adenocarcinoma in situ (pre-invasive lesion) or minimally invasive adenocarcinoma in stage IA lung cancer patients with solitary ground-glass opacity nodules. This retrospective study enrolled 58 consecutive stage IA pulmona...

متن کامل

Ground-glass Opacity Detection Based on Correlation between Successive Slice Images

Medical imaging systems such as computed tomography, magnetic resonance imaging provided a high resolution image for powerful diagnostic tool in visual inspection fields by physician. Especially MDCT image can be used to obtain detailed images of the pulmonary anatomy, including pulmonary diseases such as the pulmonary nodules, the pulmonary vein, etc. In the medical image processing technique,...

متن کامل

Identification of preoperative prediction factors of tumor subtypes for patients with solitary ground-glass opacity pulmonary nodules

BACKGROUND Recent wide spread use of low-dose helical computed tomography for the screening of lung cancer have led to an increase in the detection rate of very faint and smaller lesions known as ground-glass opacity nodules. The purpose of this study was to investigate the clinical factors of lung cancer patients with solitary ground-glass opacity pulmonary nodules on computed tomography. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008