Primary aldosteronism: diagnostic accuracy of the losartan and captopril tests.
نویسندگان
چکیده
BACKGROUND To assess whether angiotensin-II receptor blockers (ARBs) offer any additional advantage in confirming the diagnosis of primary aldosteronism (PA) and their use in the differentiation of PA subtypes. METHODS A prospective, cohort, head-to-head study was conducted between July 2003 and July 2006. A total of 135 patients received captopril and losartan tests to confirm the diagnosis of PA in the TAIPAI (Taiwan Primary Aldosteronism Investigation) intervention. RESULTS In total, 71 patients were diagnosed with PA. The area under the receiver-operating characteristic (ROC) curve of the postcaptopril plasma aldosterone concentration (PAC) was significantly less than that of the postlosartan PAC (0.744 vs. 0.829, P = 0.038). Using an aldosterone-renin ratio (ARR, ng/dl per ng/ml/h) >35 with a PAC >10 ng/dl, the specificity was 89.1% vs. 93.8% and the sensitivity was 66.2% vs. 84.5 % for the captopril test vs. the losartan test, respectively. With respect to the losartan test, the accuracy was 88.9%, the agreement was good (k = 0.778), and there was no disagreement with the McNemar test (P = 0.118). Losartan had the advantage of a better negative predictive value to exclude PA when patients were referred with a serum potassium (SK) level <3.8 mmol/l. When a postlosartan ARR >60 was the cutoff value, the positive predictive value was 82% with a negative predictive value of 57% in distinguishing aldosterone-producing adenomas (APAs) from idiopathic hyperaldosteronism (IHA). CONCLUSIONS The postlosartan ARR and PAC were shown to have better accuracy for the diagnosis of PA than the captopril test. With a postlosartan ARR >60, APAs can be adequately differentiated from IHA.
منابع مشابه
Diagnostic value of the post-captopril test in primary aldosteronism.
Primary aldosteronism is a disorder with hypertension, hypokalemia, increased plasma aldosterone, and suppressed renin activity. A random plasma aldosterone/renin activity (PA/PRA) >65 (conventional units ratio [CUR] >30) has been proposed as a screening test. We have retrospectively determined the value of the post-captopril plasma aldosterone/renin activity (CAPT PA/PRA) test for the diagnosi...
متن کاملCaptopril suppression versus salt loading in confirming primary aldosteronism.
This prospective study was designed to compare the captopril suppression test with the salt-loading approach to confirm the diagnosis of primary aldosteronism. A total of 49 patients were referred with a presumed diagnosis of primary aldosteronism. The captopril test was performed in the morning with patients in the seated position after overnight fasting. Blood samples for plasma aldosterone w...
متن کاملQuantitative Value of Aldosterone‐Renin Ratio for Detection of Aldosterone‐Producing Adenoma: The Aldosterone‐Renin Ratio for Primary Aldosteronism (AQUARR) Study
BACKGROUND Current guidelines recommend use of the aldosterone-renin ratio (ARR) for the case detection of primary aldosteronism followed by confirmatory tests to exclude false-positive results from further diagnostic workup. We investigated the hypothesis that this could be unnecessary in patients with a high ARR value if the quantitative information carried by the ARR is taken into due consid...
متن کاملComparison of the captopril and the saline infusion test for excluding aldosterone-producing adenoma.
We performed a prospective head-to-head comparison of the accuracy of the captopril test (CAPT) and the saline infusion test (SAL) for confirming primary aldosteronism due to an aldosterone-producing adenoma (APA) in patients with different sodium intake. A total of 317 (26.9%) of the 1125 patients screened in the Primary Aldosteronism Prevalence in Italy Study underwent both CAPT and SAL. They...
متن کاملScreening for primary aldosteronism with a logistic multivariate discriminant analysis.
OBJECTIVE Primary aldosteronism (PA) is the most common endocrine cause of curable hypertension, but no single test unequivocally identifies it. Accordingly, we investigated the usefulness of a logistic multivariate discriminant analysis (MDA) approach for PA screening. DESIGN Generation of a logistic MDA function based on retrospective analysis of biochemical tests in a large cohort of refer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of hypertension
دوره 22 8 شماره
صفحات -
تاریخ انتشار 2009