Heart rate monitoring on the stroke unit. What does heart beat tell about prognosis? An observational study
نویسندگان
چکیده
BACKGROUND Guidelines recommend maintaining the heart rate (HR) of acute stroke patients within physiological limits; data on the frequency and predictors of significant deviations from these limits are scarce. METHODS Demographical data, stroke risk factors, NIH stroke scale score, lesion size and location, and ECG parameters were prospectively assessed in 256 patients with ischemic stroke. Patients were continuously monitored for at least 24 hours on a certified stroke unit. Tachycardia (HR ≥ 120 bpm) and bradycardia (HR <45 bpm) and cardiac rhythm (sinus rhythm or atrial fibrillation) were documented. We investigated the influence of risk factors on HR disturbances and their respective influence on dependence (modified Rankin Scale ≥ 3 after three months) and mortality. RESULTS HR ≥ 120 bpm occurred in 39 patients (15%). Stroke severity (larger lesion size/higher NIHSS-score on admission), atrial fibrillation and HR on admission predicted its occurrence. HR <45 bpm occurred in 12 patients (5%) and was predicted by lower HR on admission. Neither HR ≥ 120 nor HR <45 bpm independently predicted poor outcome at three moths. Stroke location had no effect on the occurrence of HR violations. Clinical severity and age remained the only consistent predictors of poor outcome. CONCLUSIONS Significant tachycardia and bradycardia are frequent phenomena in acute stroke; however they do not independently predict clinical course or outcome. Continuous monitoring allows detecting rhythm disturbances in stroke patients and allows deciding whether urgent medical treatment is necessary.
منابع مشابه
Effect of endotoxemia on heart rate dynamics in rat isolated perfused hearts
Introduction: Beat-to-beat variation in heart rate shows a complex dynamics, and this complexity is changed during systemic inflammatory response syndrome (e.g. sepsis). It is not known whether or not cardiac pacemaker dynamical rhythm is affected by sepsis. The aim of this study was to investigate heart rate dynamics of isolated heart as well as expression of pacemaker channels (HCN) in a r...
متن کاملPrevalence of Heart Failure in Patients With Ischemic Stroke: A Descriptive Study
Background: Cerebrovascular Accident (CVA) is the second cause of death and disability in the world. Heart failure can co-occur with CVA and increases the risk of death and disability in patients. Objectives: This study aimed to evaluate the prevalence of heart failure in patients with ischemic stroke. Materials & Methods: In this cross-sectional study, the information of patients with ischem...
متن کاملDesign of a Simple and Low-Cost Microcontroller Based Medicare Device for Heart Beat Monitoring
Heart beat monitoring is vital to ensuring healthiness of the human cardiovascular system, but availability of a simple and low-cost heart beat monitoring device that does not require expert medical personnel to handle still remains a challenge especially in rural and semiurban areas of developing countries like Nigeria. This paper describes the design and implementation of a simple, reliable, ...
متن کاملPhysiological correlates of beat-to-beat, ambulatory, and day-to-day home blood pressure variability after transient ischemic attack or minor stroke.
BACKGROUND AND PURPOSE Visit-to-visit and day-to-day variability in systolic blood pressure (SBP) are associated with an increased risk of stroke, more strongly than variability on 24-hour ambulatory BP monitoring, but underlying physiological mechanisms are unclear. We related potentially relevant physiological characteristics to beat-to-beat, ambulatory, and day-to-day BP variability to ident...
متن کاملTranscranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve
Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...
متن کامل