Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test
نویسندگان
چکیده
PURPOSE To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP). METHODS Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised, counterbalanced design. Participants completed two RAMP protocols (20 W·min-1) in week 1, followed by two PRETmax in week 2, or vice versa. The PRETmax comprised five, 2-min stages clamped at Ratings of Perceived Exertion (RPE) 11, 13, 15, 17 and 20. Participants changed power output (PO) as often as required to maintain target RPE. Gas exchange variables (oxygen uptake, carbon dioxide production, minute ventilation), heart rate (HR) and PO were collected throughout. Differentiated RPE were collected at the end of each stage throughout trials. RESULTS For relative [Formula: see text], coefficient of variation (CV) was equal to 4.1% and 4.8%, with ICC(3,1) of 0.92 and 0.85 for repeated measures from PRETmax and RAMP, respectively. Measurement error was 0.15 L·min-1 and 2.11 ml·kg-1·min-1 in PRETmax and 0.16 L·min-1 and 2.29 ml·kg-1·min-1 during RAMP for determining absolute and relative [Formula: see text], respectively. The difference in [Formula: see text] between PRETmax and RAMP was tending towards statistical significance (26.2 ± 5.1 versus 24.3 ± 4.0 ml·kg-1·min-1, P = 0.055). The 95% LoA were -1.9 ± 4.1 (-9.9 to 6.2) ml·kg-1·min-1. CONCLUSION The PRETmax can be used as a reliable test to measure [Formula: see text] during handcycle exercise in recreationally active participants. Whilst PRETmax tended towards significantly greater [Formula: see text] values than RAMP, the difference is smaller than measurement error of determining [Formula: see text] from PRETmax and RAMP.
منابع مشابه
Reliability and validity of an agility‐like incremental exercise test with multidirectional change‐of‐direction movements in response to a visual stimulus
The aim of the study was to evaluate the reliability and validity of cardiorespiratory and metabolic variables, that is, peak oxygen uptake (V'O2peak) and heart rate (HRpeak), obtained from an agility-like incremental exercise test for team sport athletes. To investigate the test-retest reliability, 25 team sport athletes (age: 22 ± 3 years, body mass: 75 ± 7 kg, height: 182 ± 6 cm) performed a...
متن کاملTest-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table
BACKGROUND Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively in...
متن کاملOxygen uptake during functional activities after stroke—Reliability and validity of a portable ergospirometry system
BACKGROUND People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the fi...
متن کاملA Rapidly-Incremented Tethered-Swimming test for Defining Domain-Specific Training Zones
The purpose of this study was to investigate whether a tethered-swimming incremental test comprising small increases in resistive force applied every 60 seconds could delineate the isocapnic region during rapidly-incremented exercise. Sixteen competitive swimmers (male, n = 11; female, n = 5) performed: (a) a test to determine highest force during 30 seconds of all-out tethered swimming (Favg) ...
متن کاملThe steep ramp test in healthy children and adolescents: reliability and validity.
PURPOSE This study aimed to examine the reliability and validity of the steep ramp test (SRT), a feasible, maximal exercise test on a cycle ergometer that does not require the use of respiratory gas analysis, in healthy children and adolescents. METHODS Seventy-five children were randomly divided in a reliability group (n = 37, 17 boys and 20 girls; mean ± SD age = 13.86 ± 3.22 yr), which per...
متن کامل