Extracellular volume fraction mapping at 3T with non-rigid image co-registration
نویسندگان
چکیده
National Heart Centre, Singapore, Singapore Full list of author information is available at the end of the article Figure 1 Native myocardial T1 map without (left) and with (right) motion correction at 3T. Arrows indicate motion misalignment that was corrected by the proposed approach. Le et al. Journal of Cardiovascular Magnetic Resonance 2016, 18(Suppl 1):P32 http://www.jcmr-online.com/content/18/S1/P32
منابع مشابه
بهبود سرعت "انطباق مبتنی بر روش برش گراف" جهت انطباق غیر صلب تصاویر تشدید مغناطیسی مغز
Image processing methods, which can visualize objects inside the human body, are of special interests. In clinical diagnosis using medical images, integration of useful data from separate images is often desired. The images have to be geometrically aligned for better observation. The procedure of mapping points from the reference image to corresponding points in the floating image is called Ima...
متن کاملTarget volume coronary MRA revisited: usefulness of non-rigid reregistration of multi-frame 3D MRA acquisitions at 3T
Background Free-breathing whole-heart coronary MR angiography (MRA) is an established method that can visualize all coronary arteries within a single acquisition. However, a long acquisition time and suboptimal arterial signal due to thick SLAB are major limitations of 3T gradient-echo whole-heart coronary MRA without contrast. Alternatively, target-volume coronary MRA can be used to visualize ...
متن کاملHigh-resolution modified look-locker inversion recovery (HR-MOLLI) for RV extracellular volume fraction at 3T and 1.5T: A feasibility study
Background Cardiac MR (CMR) is the reference standard for assessing macroscopic myocardial scar. Determination of the extracellular volume fraction (ECV) by T1 estimation using the modified Look-Locker inversion recovery (MOLLI) correction enables quantitation of diffuse fibrosis. The purpose of this study is to evaluate the feasibility and reproducibility of an optimized high-resolution MOLLI ...
متن کاملCorrection of local deformations in fMRI by 3D non-linear warping in map-slice-to-volume approach
Zntroduction Recently, we have demonstrilted the capability of retrospectively mapping a slice image into rin anatomical reference volume (i.e. map-slice-to-volume, MSV) from the same subject using a simple rigid body transformation of $x degrees of freedom (DOF) [l]. In practice, deformation in a sliQe image is often presented as a nonlinear warping problem that his not limited to the imaging ...
متن کاملCalculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model
Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2016