Hand-assisted, conventional and laparoendoscopic single-site surgery for partial nephrectomy without ischemia using a microwave tissue coagulator.
نویسندگان
چکیده
PURPOSE We report our experience of minimally invasive partial nephrectomy without ischemia using a microwave tissue coagulator (MTC) for hand-assisted laparoscopic partial nephrectomy (HALPN), conventional laparoscopic partial nephrectomy (CLPN), and laparoendoscopic single-site surgery for partial nephrectomy (LESSPN). We retrospectively compared the results of these techniques to better define the individual role and the benefits. MATERIALS AND METHODS From July 2005 to September 2012, 28 patients with small and exophytic renal tumors underwent HALPN (n = 12), CLPN (n = 10) and LESSPN (n = 6). In these procedures, the surgeon used an MTC for circumferential coagulation around the tumor. After coagulation, the tumor was resected without renal pedicle clamping. RESULTS The mean operative time was 259, 194 and 174 min for the HALPN, CLPN and LESSPN groups respectively. Two patients (one in HALPN group and one in LESSPN group) converted to laparotomy due to an inability to maintain hemostasis; however, there were no conversions to ischemic partial nephrectomy or radical nephrectomy. No differences between HALPN, CLPN and LESSPN were noted in terms of estimated blood loss, measured analgesic requirements, outcomes, or complications. CONCLUSION We believe that these techniques are feasible and that they minimize the risk of unexpected collateral thermal damage by appropriate MTC needle puncture. When deciding to use HALPN, CLPN or LESSPN, our findings suggest that the choice of surgical approach should depend on the patient's individual circumstance.
منابع مشابه
Transumbilical laparoendoscopic single-site partial nephrectomy using a microwave tissue coagulator
Transumbilical single-port laparoscopy has emerged as a method to further enhance cosmetic benefits and reduce morbidity. We present an initial experience with transumbilical laparoendoscopic single-site partial nephrectomy (LESS-PN). A 36-year-old woman visited our hospital for the treatment of a left exophytic renal cell carcinoma, 17 mm in diameter, located at the lower pole. We decided to u...
متن کاملLaparoscopic partial nephrectomy using a microwave tissue coagulator for treating small peripheral renal tumors.
BACKGROUND Laparoscopic partial nephrectomy has been recently applied as a minimally invasive procedure. Several non-ischemic operation devices in partial nephrectomy have been developed. However, the problem related to maintenance of renal homeostasis remains. We investigated the efficacy and safety of a microwave tissue coagulator in laparoscopic partial nephrectomy. METHODS Between April 2...
متن کامل[Non-ischemic partial nephrectomy using microwave tissue coagulator].
PURPOSE The indications and the safety of non-ischemic partial nephrectomy using a microwave tissue coagulator were studied. MATERIALS AND METHODS Non-ischemic partial nephrectomy was performed on 17 kidneys of 16 patients using a microwave tissue coagulator. The diagnosis was renal tumor and renal stones in eleven and five patients, respectively. Renal tumors were less than 4 centimeters in ...
متن کاملSimultaneous Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy and Standard Radical Prostatectomy
Recently, patients with urologic malignancies are treated with robot-assisted surgery and the expanded role of robot-assisted surgery includes even those patients with two concomitant primary urologic malignancies. In an effort to further reduce port site-related morbidity, robot-assisted laparoendoscopic single-site surgery (RLESS) has been developed. Therefore, we present herein our early exp...
متن کاملMulticenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator
Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS) nonischemic laparoscopic partial nephrectomy (NI-LPN) utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS) undergoing NI-LPN between 4/2006 and 9/2009. Multiport and LESS NI-LPN utilized Habib 4X bipolar radiofrequency coagulator to f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Urology journal
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2014