Analysis of Four Aberrometers for Evaluating Lower and Higher Order Aberrations

نویسندگان

  • Fabiano Cade
  • Andrea Cruzat
  • Eleftherios I. Paschalis
  • Lilian Espírito Santo
  • Roberto Pineda
چکیده

PURPOSE To compare the measurements of lower and higher order aberrations (HOA) of 4 commonly used aberrometers. SETTING Massachusetts Eye & Ear Infirmary, Boston, USA. DESIGN Prospective, cross-sectional study, in a controlled, single-blinded fashion. METHODS Multiple readings were obtained in 42 eyes of 21 healthy volunteers, at a single visit, with each of the following aberrometers: Alcon LADARWave®, Visx WaveScan®, B & L Zywave®, and Wavelight Allegro Analyzer®. Results were compared and analyzed in regards to the lower and HOA, to the different wavefront sensing devices and software, Tscherning and Hartmann-Shack and between the Fourier and Zernike algorithms. Statistical analysis included Bland-Altman plots, Intraclass Correlation Coefficient (ICC), multiple comparison tests with Analysis of Variance and Kruskal-Wallis. Significant level was set to p<0.05 and alpha level correction was adjusted under the Bonferroni criteria. RESULTS Most measurements of all 4 aberrometers were comparable. However, statistically significant differences were found between the aberrometers in total HOA (tHOA), spherical aberration (SA), horizontal coma and astigmatism (2,2). LADARwave and Wavescan showed significant differences in tHOA (P<0.001, ICC = 0.549, LoA = 0.19±0.5) and in SA (P<0.001, ICC = 0.733, LoA = 0.16±0.37). Wavescan showed a significant difference compared to Zywave (p<0.001, ICC = 0.920, LoA = 0.09±0.13) in SA. Comparisons between Allegro Analyzer and Zywave demonstrated significant differences in both Horizontal Coma (3,1) (p<0.001, ICC = -0.207, LoA = -0.15±0.48) and Astigmatism (2,2) (P = 0.003, ICC = -0.965, LoA = 0.2±2.5). Allegro Analyzer also differed from Wavescan in Horizontal Coma (3,1) (P<0.001, ICC = 0.725, LoA = -0.07±0.25). CONCLUSIONS Although some measurements were comparable predominately in the lower order aberrations, significant differences were found in the tHOA, SA, horizontal coma and astigmatism. Our analysis suggests that sensor design contributes to agreement in lower order aberrations, and Fourier and Zernike expansion might disagree in higher order aberrations. Therefore, comparison between aberrometers was generally possible with some exceptions in higher order measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the comparability and repeatability of four wavefront aberrometers.

PURPOSE To compare total ocular aberrations and corneal aberrations identified with four different aberrometers and to determine the repeatability and interobserver variability. METHODS In this prospective comparative study, 23 healthy subjects underwent bilateral examination with four aberrometers: the Irx3 (Hartmann-Shack; Imagine Eyes, Orsay, France), Keratron (Hartmann-Shack; Optikon, Rom...

متن کامل

Refractive Surgery Feature Story

SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 35 T he introduction of wavefront-sensing techniques to ophthalmology has redefined the clinical meaning of refractive error. Now, all imperfections in the components and materials within the eye that cause light rays to deviate from their desired path are referred to as optical aberrations. Lower-order aberrations (defocus and astigmati...

متن کامل

Comparison of Internal and Total Optical Aberrations for 2 Aberrometers: iTrace and OPD Scan

PURPOSE To compare and evaluate the total and internal aberrations measured by two aberrometers: the laser ray tracing aberrometer (iTrace, Tracey Technology) and the automatic retinoscope aberrometer (OPD Scan, Nidek). METHODS A total of 54 healthy eyes were enrolled in the study. Following pupil dilation, aberrations were measured with the iTrace and OPD Scan. We compared the aberrations ob...

متن کامل

Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers

BACKGROUND To assess the precision and agreement of measurements of higher order aberrations (HOAs) obtained with a ray tracing aberrometer (iTrace) and a Hartmann-Shack aberrometer (Topcon KR-1 W). METHODS Prospective evaluation of the diagnostic test. Data from the right eyes of 92 normal subjects obtained using the two devices were included in this study. Two observers performed 3 consecut...

متن کامل

Higher order aberrations using the NIDEK OPD-Scan and AMO WaveScan.

PURPOSE To compare higher order aberrations measured with the NIDEK OPD-Scan and AMO WaveScan. METHODS Third- to sixth-order higher order aberrations were measured in 1072 eyes using the OPD-Scan and WaveScan. Means, standard deviations, confidence intervals, limits of agreement, and intraclass correlation coefficients (ICC) were calculated. RESULTS Aberrations of greatest magnitude with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013