BACKGROUND The aim of this study was to compare human and animal skin irritation data with results of selected in vitro methods, including HET-CAM test, Neutral Red Release Assay, Neutral Red Uptake Assay and EpiOcular eye irritation test and with already existing data of eye irritation obtained from animal experiments. METHODS Chemicals employed in previous skin irritation validation studies and commercially available cosmetic formulations were subjected to further testing using in vitro methods Neutral Red Release (NRR) assay, Neutral Red Uptake (NRU) assay, HET-CAM test and EpiOcular assay. RESULTS The study revealed that skin irritants are not necessarily eye irritants; specifically volatile or solid materials may be misclassified. NRR assay provided false negative results in case of substances with fixative effect or not removable under standard washing procedure, emphasizing the role of microscopical evaluation as a crucial additional endpoint. Although overpredictive, HET-CAM test provided the lowest false negative rate. The most aggressive cosmetic formulation was correctly identified by EpiOcular assay, in accordance with NRU and NRR assays results, while HET-CAM test correctly identified the mildest formulation. CONCLUSIONS Each of the in vitro methods is related to a specific endpoint of ocular irritation and provides only partial information on the mode of action of the tested material. Despite good reproducibility of individual in vitro assays, only the weight-of-evidence approach and results of multiple selected in vitro tests can allow for estimation of eye irritation hazard in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CON4EI: CONsortium for in vitro Eye Irritation testing strategy - EpiOcular™ time-to-toxicity (EpiOcular ET-50) protocols for hazard identification and labelling of eye irritating chemicals.

Assessment of acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment for all drivers of classification. A set of 80 reference chemicals (38 liquids and 42 solids) was tested wit...

متن کامل

Combined in vitro tests as an alternative to in vivo eye irritation tests.

Accurate methods that test the eye irritation potential of chemicals, which do not involve the use of animals, are needed to meet new regulatory standards. We evaluated the applicability and predictive capacity of five in vitro tests for eye irritation: the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) assay; the Chorioallantoic Membrane-Trypan Blue Staining (CAM-TBS) assay; the Fluorescein...

متن کامل

Evaluation of a human corneal epithelial cell line as an in vitro model for assessing ocular irritation.

A human corneal epithelial cell line, 10.014 pRSV-T (HCR-T cells), has been used to develop a three-dimensional in vitro model of the human corneal epithelium (HCE-T model). HCE-T cells form a stratified culture when grown at the air-liquid interface on a collagen membrane in serum-free medium. This model served as the basis for assays which supported the ocular irritancy assessment of water-so...

متن کامل

Comparison of human skin irritation and photo-irritation patch test data with cellular in vitro assays and animal in vivo data

Replacement of the rabbit Draize skin irritation test or the animal photo-irritation test is in course in Europe under the REACH chemical strategy and the Cosmetics Directive. Various in vitro protocols, including 3D skin models, have been assessed. One key difficulty in determining the validity of alternative in vitro methods is that the in vivo animal data is both scarce and often of limited ...

متن کامل

Formulation and evaluation of Moxifloxacin hydrochloride ocular nanoparticles

The objective of the present study was to prepare controlled release formulation of Moxifloxacin hydrochloride ocular nanoparticles. The nanoparticles were prepared by solvent displacement method using Eudragit RL 100 as a polymer. Different formulations were prepared by varying the ratios of drug and polymer and varying the ratios of organic and aqueous phase. The formulations were evaluated i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuro endocrinology letters

دوره 35 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2014