Potentially fatal vaporizer incident.

نویسندگان

  • V K Jagannathan
  • S A Nortcliffe
چکیده

EDITOR: We wish to report a potentially fatal critical incident that occurred during an elective operating theatre list. A similar problem [1] has been recently highlighted by the MHRA but without the emphasis of its potentially fatal nature (Fault in Draeger Vapor 2000/D-Vapor Vaporizer series with the interlocking device, MDA/2006/030) [2]. This series of vaporizers for isoflurane and sevo-flurane has an interlocking safety system consisting of a hole with a nib in the coloured disk on the top of the vaporizer, at 1808 to each other. This prevents the locking bar being inserted into the hole unless the vaporizer is turned off. It is known that damage to or loss of this plastic nib can result in two vaporizers being turned on simultaneously [3]. The presence of a unilateral nib at the 5% delivery mark masks the absence of the second nib at the 0% delivery mark due to the nature of the vaporizer position on the anaesthetic machine at the left-hand side (Fig. 1). This machine thus passed the routine AAGBI Recommendations for Checking Anaesthetic Equipment [4]. On transfer of the patient to the operating room, initially isoflurane was switched on to 1–2%. The desflurane vaporizer was then mounted as the anaes-thetist's agent of choice and switched on after switching off the isoflurane vaporizer – or so we thought. What happened next is shown in Figure 2. The vaporizer on the left is locked at 5% isoflurane. This was caused when the anaesthetist inadvertently turned the vapor-izer dial anticlockwise to switch off instead of in a clockwise direction (i.e. the wrong way) and engaged the interlocking device, which then allowed operation of the desflurane vaporizer. We recognized this mistake a few seconds after it occurred preventing any harm to the patient. The interlocking device required considerable force to disengage from the isoflurane vaporizer. Two issues need to be addressed: 1. Awareness of this potential error as the number of general anaesthetics given daily with these agents is large, increasing the chances of a similar episode that might not be corrected so speedily. 2. The manufacturer needs to urgently rectify this problem. Figure 1. Damaged nib. Figure 2. Isoflurane vaporizer at 5% with interlocking device on and desflurane also switched on at 4%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isoflurane cracks the polycarbonate connector of extra-corporeal circuit -A case report-

Cardiopulmonary bypass (CPB) is widely used for cardiac surgery by virtue of its proven safety over the course of its use during the past half century. Even though perfusion is safer, incidents still occur. During the repair of a ventricular-septal defect in an 11-month-old infant, we experienced a critical incident related to the potential hazardous effect of volatile anesthetics on the polyca...

متن کامل

The yellow discoloration of desflurane

rane (Suprane, Baxter Healthcare, Puerto Rico, USA) in the Dräger vaporizer (Dräger D-vapor, Dräger Medical GmbH, Lübeck, Germany) had turned yellow while filling the vaporizer (Fig. 1). We immediately changed the vaporizer. Yellow discoloration of desflurane occurs relatively infrequently and is not widely known; however, this was the second incident in our hospital. The yellowing of desfluran...

متن کامل

Managing Clinical Incidents in General Practice

Clinical incident in general practice can be potentially harmful, costly and even fatal. Studies in general practice in Australia have shown that over three quarter of these incidents are preventable [Bhasale et. al. 1998]. We describe in this paper a holistic model which amalgamates three knowledge management methodologies (ontological, rulebased, and causal) and case based reasoning to provid...

متن کامل

The Diamedica Draw-Over Vaporizer: a comparison of a new vaporizer with the Oxford Miniature Vaporizer.

The Diamedica Draw-Over Vaporizer (DDV) has been developed as an alternative to the Oxford Miniature Vaporizer (OMV). Both can function as draw-over or plenum vaporizers. The performances of these two vaporizers were compared under conditions simulating intermittent positive pressure ventilation (IPPV) and continuous flow (CF). Series 1 experiments were conducted with the vaporizers in water ba...

متن کامل

Hypersensitivity Pneumonitis by a Cool-Mist Vaporizer a Detailed Microbiologic and Immunologic Study

A patient with hypersensitivity pneumonitis caused by a contaminated cool-mist vaporizer was evaluated. A detailed microbiologic and immunologic study was done, and a Pseudomonas species was isolated as the possible causative organism by inhalational provocative and serologic tests.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2008