Comparison of sampling techniques for studies of nitrous oxide pollution.
نویسندگان
چکیده
The retention of nitrous oxide in samples of nitrous oxide in air held in disposable plastic syringes, glass syringes and custom-made nylon film bags was studied by means of gas chromatography at intervals of 90 min, 24, 48 and 120 h after filling the containers. After 24 h the nylon bags retained a mean concentration of 94.5% of the original concentration of nitrous oxide. The disposable plastic syringes and glass syringes were unsatisfactory and retained only 80% of the original concentration of nitrous oxide after 90 min. These values decreased to 51% and 31% of the original concentration of nitrous oxide respectively at 24 and 48 h.
منابع مشابه
Nitrous Oxide Pollution: a Geostatistical Method to Assess Spatial Distribution of Anaesthetic Gases and Hospital Staff Exposure
In this study we evaluated the diffusion of nitrous oxide in a few operating rooms, using spatial data modelling techniques, in order to assess hospital staff exposure and to promote risk management. Indoor air sampling was carried out, during routine operating activity, by means of transportable infrared spectrometer, with geostatistical techniques. We detected high average concentrations of n...
متن کاملP110: Nitrous Oxide and Neuroinflammation
Nitrous oxide was an anaesthetic gas that was used for many years. There were many anaesthetic drugs in operations with many side effects. Nitrous oxide had some side effects too. But it was a safe gas in many times. In hospital personnel who worked in operating rooms exposure to this gas was important. The objective of this study was the introduction of nitrous oxide and neurologic side ...
متن کاملEnvironmental monitoring during gaseous induction with sevoflurane.
Recent research has shown that gaseous induction in adults with sevoflurane is an acceptable technique. This study was undertaken to assess if gaseous induction using sevoflurane carried in both oxygen alone, and in nitrous oxide and oxygen combined, would provide acceptable pollution levels. As an occupational exposure standard has not been set for sevoflurane, we used the target level of 20 p...
متن کاملNitrous oxide and formiminoglutamic acid: excretion in surgical patients and anaesthetists.
We have investigated the possible toxicity of nitrous oxide on vitamin B12 and its sequelae upon folic acid metabolism using the urine formiminoglutamic acid excretion test, an index of the functional state of folate metabolism. Ten control subjects not exposed to nitrous oxide and five patients receiving limb surgery under local anaesthesia excreted normal amounts of formiminoglutamic acid in ...
متن کاملDFT Study of Nitrous Oxide Adsorption on the Surface of Pt-Decorated Graphene
In the present study we search potential of Pt-decorated graphene (PtG) as a new nanostructure adsorbent for nitrous oxide (N2O) using density functional theory (DFT). After fully relaxation of different possible orientations of N2O-PtG complex, we distinguished two optimized configurations for this system; 1- terminal N-side of gas is oriented towards Pt so that the molec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 50 11 شماره
صفحات -
تاریخ انتشار 1978