Tin Content Determination in Canned Fruits and Vegetables by Hydride Generation Inductively Coupled Plasma Optical Emission Spectrometry

نویسندگان

  • Sanda Rončević
  • Anica Benutić
  • Ivan Nemet
  • Buga Gabelica
چکیده

Tin content in samples of canned fruits and vegetables was determined by hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES), and it was compared with results obtained by standard method of flame atomic absorption spectrometry (AAS). Selected tin emission lines intensity was measured in prepared samples after addition of tartaric acid and followed by hydride generation with sodium borohydride solution. The most favorable line at 189.991 nm showed the best detection limit (1.9 μg L(-1)) and limit of quantification (6.4 μg kg(-1)). Good linearity and sensitivity were established from time resolved analysis and calibration tests. Analytical accuracy of 98-102% was obtained by recovery study of spiked samples. Method of standard addition was applied for tin determination in samples from fully protected tinplate. Tin presence at low-concentration range was successfully determined. It was shown that tenth times less concentrations of Sn were present in protected cans than in nonprotected or partially protected tinplate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Linear and Nonlinear Multivariate Classification of Iranian Bottled Mineral Waters According to Their Elemental Content Determined by ICP-OES

The combinations of inductively coupled plasma-optical emission spectrometry (ICP-OES) and three classification algorithms, i.e., partial least squares discriminant analysis (PLS-DA), least squares support vector machine (LS-SVM) and soft independent modeling of class analogies (SIMCA), for discriminating different brands of Iranian bottled mineral waters, were explored. ICP-OES was used for th...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Determination of Tin in Canned Foods by Inductively Coupled Plasma-Mass Spectrometry

Most foods contain very low concentrations of tin, usually below 10 mg/kg, although canned foods may contain higher concentrations as a result of the slow dissolution of the tin coating used on the inside of some food cans to protect the steel body of the can from corrosion. An inductively coupled plasma-mass spectrometry (ICP-MS) method following microwave digestion was developed and evaluated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012