Reactive power compensation for linear and non linear loads by using active and passive filter for smart grid applications

نویسندگان

  • Vikas Kumar Chandra
  • Mahendra Kumar Pradhan
چکیده

In this work a new control strategy for simulation of three phase power filter for power quality improvement is used .This filter consists of shunt passive LC power filter and series active filter, with nonlinear and linear loads and also with variation in the source impedance. A new control method based on dual formulation of instantaneous reactive power vectorial theory is applied by considering a balanced and resistive load as reference load, so that the voltage waveform injected by the active filter is able to attain the objective of achieving reactive power compensation. This also helps in eliminating load current harmonics and also in balancing asymmetrical loads i.e., for achieving ideal behaviour for the set hybrid filter load, Total Harmonic Distortion (THD) is reduced and power factor is improved. This method improves passive filter compensation characteristics without depending on system impedance, avoids the danger of passive filter behaves as harmonic drain of close loads and avoiding series and / or parallel resonance problems. And compensation is also possible with variable loads without detuning the passive filter. And is applied for creating LG/LL faults at the source side. The results show that the active filter improves the compensation characteristics of the passive filter and reactive power is compensated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure

Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...

متن کامل

Very Fast Load Flow Calculation Using Fast-Decoupled Reactive Power Compensation Method for Radial Active Distribution Networks in Smart Grid Environment Based on Zooming Algorithm

Distribution load flow (DLF) calculation is one of the most important tools in distribution networks. DLF tools must be able to perform fast calculations in real-time studies at the presence of distributed generators (DGs) in a smart grid environment even in conditions of change in the network topology. In this paper, a new method for DLF in radial active distribution networks is proposed. The ...

متن کامل

Model Predictive Control of Distributed Energy Resources with Predictive Set-Points for Grid-Connected Operation

This paper proposes an MPC - based (model predictive control) scheme to control active and reactive powers of DERs (distributed energy resources) in a grid - connected mode (either through a bus with its associated loads as a PCC (point of common coupling) or an MG (micro - grid)). DER may be a DG (distributed generation) or an ESS (energy storage system). In the proposed scheme, the set - poin...

متن کامل

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016