Advances in the development of a dissolution method for the attribution of iridium source materials

نویسندگان

  • A P J Hodgson
  • K E Jarvis
  • R W Grimes
  • O J Marsden
چکیده

To assist in nuclear forensic investigations, new techniques are required to evaluate radioactive materials that may be discovered outside of regulatory control. Using a recently developed pressure digestion method for iridium powder, assessments have been made of this techniques suitability for undertaking iridium target material evaluations. In addition to determining the reaction conditions necessary for total dissolution, these investigations have provided an insight into the elemental impurities that are present within unirradiated iridium targets that are used in QSA Global radiography sources, and established the speciation of the iridium solutions that are formed during this process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

Attribution Bias in schizophrenian patients who have auditory hallucination

Introduction: Concerning cognitivism, psychotic experiences (hallucination) of schizophrenic patiets have been hypothesized to originate from a fundamentally cognitive biases. Methods: To explor the idea that attribution bias may underlin appearance of auditory hallucination, in the current descriptive study, a source-monitoring task were used to compare healthy controles with relatives of indi...

متن کامل

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 311  شماره 

صفحات  -

تاریخ انتشار 2017