Agreement in gait speed from smartphone and stopwatch for five meter walk in laboratory and clinical environments.

نویسندگان

  • Rahul Soangra
  • Thurmon E Lockhart
چکیده

Gait speed is suggested as an independent predictor of post-operative morbidity and mortality in elderly cardiovascular disease (CVD) patients. Society of thoracic surgeons has recently classified gait speed as the only important indicator of health for CVD patients. It has been seen that patients with slow gait speed above 70 years of age, taking more than 6 seconds to walk 5 meters are particularly at high risk for adverse outcomes. Twelve young participants walked in their self-selected, slow and fast speed with five reflective markers at sternum and heels and toes of both feet in laboratory environment. A smartphone was affixed at the pelvis using a smartphone holster. Simultaneously, an examiner used stopwatch to record the elapsed time necessary to cross 5 meter distance. Smartphone based app also computed gait speed. Intra-class correlation coefficients comparing velocities from camera system, smartphone and stopwatch systems were found to be highly reliable (ICC (3,k)=0.82) for slow walking speed. Similarly, fairly good reliability were found for fast (ICC(3,k)=0.70) and normal walking speed (ICC(3,k)=0.66). Five CVD patients were tested in clinical environment with smartphone and its feasibility was assessed for gait speed. This study shows that the smartphone and stopwatch gait speed methods have clinically acceptable agreement for the measurement of gait velocity in the two different environments. The smartphone based reliable measurements could help patients on their own to assess operative risks and health during perioperative period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in Gait Pattern During Smartphone and Tablet Use

Objectives: There exists no study concerning gait pattern while engaging in dual-task activities on different sizes of mobile devices. The present study aimed to compare gait patterns during normal walking, walking with smartphone use, and walking with tablet use.  Methods: Seventeen healthy female participants with an age range of 19-24 years (mean±SD age: 20.29±1.61 years, weight: 49.82±4.46...

متن کامل

Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments

Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10M...

متن کامل

Measuring gait speed in the out-patient clinic: methodology and feasibility.

BACKGROUND Gait speed is a simple physical function measure associated with key outcomes in the elderly population. Gait speed measurements may improve clinical care in patients with COPD. However, there is a knowledge gap about the reliability and variability of gait speed testing protocols in COPD. We evaluated established techniques of measuring gait speed in patients with COPD and assessed ...

متن کامل

Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients: Timed Up and Go and Gait Speed Assessments

Objectives: Ankle Foot Orthoses (AFOs) are widely utilized to improve walking ability in hemiplegic patients. The present study aimed to evaluate the effect of Rocker bar Ankle Foot Orthosis (RAFO) on functional mobility in post-stroke hemiplegic patients. Methods: Fifteen hemiplegic patients (men and women) who were at least 6-months poststroke and able to walk without an assis...

متن کامل

Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals

BACKGROUND Manual measurement of 4-meter gait speed by a stopwatch is the gold standard test for functional assessment in older adults. However, the accuracy of this technique may be biased by several factors, including intra- and inter-operator variability. Instrumental techniques of measurement using accelerometers may have a higher accuracy. Studies addressing the concordance between these t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical sciences instrumentation

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2014