A novel approach to fit testing of the N95 respirator in real time in a clinical setting

نویسندگان

  • PP-L Or
  • JW-Y Chung
  • TK Wong
چکیده

The instant measurements provided by the Portacount fit-test instrument have been used as the gold standard in predicting the protection of an N95 respirator in a laboratory environment. The conventional Portacount fit-test method, however, cannot deliver real-time measurements of face-seal leakage when the N95 respirator is in use in clinical settings. This research was divided into two stages. Stage 1 involved developing and validating a new quantitative fit-test method called the Personal Respiratory Sampling Test (PRST). In Stage 2, PRST was evaluated in use during nursing activities in clinical settings. Eighty-four participants were divided randomly into four groups and were tested while performing bedside nursing procedures. In Stage 1, a new PRST method was successfully devised and validated. Results of Stage 2 showed that the new PRST method could detect different concentrations and different particle sizes inside the respirator while the wearer performed different nursing activities. This new fit-test method, PRST, can detect face seal leakage of an N95 respirator being worn while the wearer performs clinical activities. Thus, PRST can help ensure that the N95 respirator actually fulfils its function of protecting health-care workers from airborne pathogens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing real-time performances of N95 respirators for health care workers by simulated workplace protection factors

To assess performances of N95 respirators for Health Care Workers (HCWs) in a simulated health-care setting, we measured the Simulated Workplace Protection Factors (SWPFs) in real-time from the volunteers. A total of 49 study subjects, wearing 3 M respirator Model N95 1860 and 1860S, were fit tested using the OSHA Exercise Regimen. The test subjects were asked to perform simulated scenarios, in...

متن کامل

Practices of Japanese nurses for the preparation of N95 respirators.

A delay in the diagnosis of tuberculosis (TB) is a public health problem in Japan. This delay may increase the chance of a TB patient visiting in a medical institution without a TB ward. We evaluated the practices of nurses for fit testing and seal checking their N95 respirator masks at hospitals without tuberculosis wards in Kanagawa, Japan. Of 36 nurses who participated in a medical course on...

متن کامل

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Effect of upper strap downward displacement on n95 filtering facepiece respirator fit factors: a pilot study.

Fifteen subjects underwent three replicates of quantitative respirator fit-testing with N95 filtering facepiece respirators that were donned with the upper strap high on the occiput, as per the manufacturers' donning instructions. Each fit-test was immediately followed by repeat fit-testing with the upper strap downwardly displaced to the level of the ear sulcus to determine any change in fit f...

متن کامل

A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers

BACKGROUND We compared the efficacy of medical masks, N95 respirators (fit tested and non fit tested), in health care workers (HCWs). METHODS A cluster randomized clinical trial (RCT) of 1441 HCWs in 15 Beijing hospitals was performed during the 2008/2009 winter. Participants wore masks or respirators during the entire work shift for 4 weeks. Outcomes included clinical respiratory illness (CR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011