Use of the labscale tangential flow diafiltrator to remove tetrameric hemoglobin from polyhemoglobin, purify hemolysate, and concentrate polyhemoglobin.

نویسندگان

  • Ada Stefanescu
  • Thomas Ming Swi Chang
چکیده

The Labscale tangential flow diafiltration system in conjunction with polyethersulfone Biomax filters (both purchased from Millipore Inc.) were used in the following studies: (1) A crucial step in the preparation of polyhemoglobin (polyHb) is the removal of tetrameric hemoglobin (Hb), which can cause adverse side-effects. The efficiency for this depends on the integrity of the 100kDa filters. Those with lower integrity were not effective whereas those with a higher integrity of 0.075ml/min were more effective. A filter with an integrity of 0.075ml/min can reduce the initial 11.2% tetrameric Hb concentration to 1.3% using a flow rate of 0.2ml/min. Higher flow rate of 2.2ml/min was not as effective. (2) Filtration with a 100kDa filter was quick and efficient in separating stroma-free hemoglobin solutions from cellular debris from hemolysate. (3) Both 5kDa and 100kDa filters are efficient in concentrating hemoglobin solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The immunological properties of stroma-free polyhemolysate containing catalase and superoxide dismutase activities prepared by polymerized bovine stroma-free hemolysate.

Crosslinking of ultrapure hemoglobin, crystalline catalase, and superoxide dismutase resulted in a soluble nanodimensional complex of polyhemoglobin-catalase-superoxide dismutase. A less expensive and more convenient way is to crosslink bovine stroma-free hemolysate (stroma-free hemolysate) that already contains hemoglobin, catalase, and superoxide dismutase into polyhemoglobin with catalase an...

متن کامل

In vitro and in vivo enzyme studies of polyhemoglobin-tyrosinase.

Melanoma is now the fifth most common type of cancer in North America. At present, there is no optimal treatment for this cancer. However, the lowering of the tyrosine level can inhibit the growth of melanoma. Unfortunately, this diet restriction cannot be humanly tolerated and causes vomiting, nausea, and severe body weight loss. To prevent these problems, we are studying a new approach involv...

متن کامل

Blood replacement with nanobiotechnologically engineered hemoglobin and hemoglobin nanocapsules.

Unlike donor red blood cells (RBCs), blood substitutes can be treated to remove infective agents and can be used on the spot or in the ambulance in emergency without the time-consuming typing and cross-matching. Donor RBC requires storage at 4 degrees and is only good for 42 days, but blood substitutes can be stored for much longer time. For example, a bovine polyhemoglobin (PolyHb) can be stor...

متن کامل

Nanobiotechnological modification of hemoglobin and enzymes from this laboratory.

Polyhemoglobin is formed by the nanobiotechnological assembling of hemoglobin molecules into soluble nanodimension complex. A further step involves the nanobiotechnological assembly of hemoglobin, catalase and superoxide dismutase into a soluble nanodimension complex. This acts both as oxygen carrier and antioxidant to prevent the oxidative effects of hemoglobin. A further step is the preparati...

متن کامل

Polyhemoglobin with different percentage of tetrameric hemoglobin and effects on vasoactivity and electrocardiogram.

There has been considerable discussions on why some types of haemoglobin-based blood substitutes increase vasoactivity whereas a very few others do not. In this study, we prepare four different types of PolyHb each containing different percentage of tetrameric hemoglobin using glutaraldehyde crosslinking and characterized to ensure that they all have the same oxygen affinity. Thus the preparati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید