Accelerated Cross-Reference Maximum Likelihood Estimates for Positron Emission Tomography
نویسندگان
چکیده
The state of art of positron emission tomography (PET) takes into account the accidental coincidence events and attenuation. The maximum likelihood estimator can handle this kind of random variation in the reconstruction of a PET image. However, the reconstruction is ill-posed and needs regularization. The boundary information, either from an expert or from the other medical modality of the same object, like the X-ray CT scan, MRI, and so forth, can be used to regularize the reconstruction. We have investigated new, efficient and robust approaches to extract the related but incomplete boundary information. Fast algorithms adapted from the expectation/conditional maximization (ECM) and space alternating generalized expectation maximization (SAGE) algorithms are proposed to accelerate the computation. The method of generalized approximate cross validation (GACV) is adjusted to select the penalty parameter from observed data quickly. The Monte Carlo studies demonstrate the improvement.
منابع مشابه
Cross-Reference Maximum Likelihood Estimates for Positron Emission Tomography
Maximum likelihood estimate (MLE) is a widely-used approach for PET image reconstruction. However, it has been shown that reconstructing emission tomography based on MLE without regularization would result in noise and edge artifacts. In the attempt to regularize the maximum likelihood estimate , in this paper, we propose a new and eecient method to incorporate the correlated but possibly incom...
متن کاملfrom projections. ” IEEE Trans Nucl Sci, 1976; NS-23: 1428-1432 [2] A.P. Dempster, N.M. Laird, D.B. Rubin “Maximum likelihood from incomplete data via
A maximum likelihood approach to emission image reconstruction from projections. Maximum likelihood from incomplete data via the EM algorithm. " A theoretical study of some maximum likelihood algorithms for emission and transmission tomography. Attenuation compensation of cone beam SPECT images using maximum likelihood reconstruction. Three-dimensional SPECT reconstruction of combined cone beam...
متن کاملCalculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملDetection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging
Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...
متن کاملCharacteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization
Objective(s): The aim of this study is to examine the effect of different smoothing filters on the image quality and SUVmax to achieve the guideline recommended positron emission tomography (PET) image without harmonization. Methods: We used a Biograph mCT PET scanner. A National Electrical Manufacturers Association (NEMA) the International Electrotechnical Commission (IEC) body phantom was fil...
متن کامل