Automated assay of plasma bromide after a single deproteinization step.
نویسندگان
چکیده
This study aimed to simplify the spectrophotometric fluorescein method for measuring plasma bromide, improve its reproducibility, and automate it. After major modifications of the method, we obtained an essentially linear calibration curve for plasma concentrations of bromide between 0 and 5.0 mmol/L. The intraassay CV for measuring bromide in the supernatants of deproteinized plasma samples (initial plasma concentrations 2.5-5.0 mmol/L) was as low as 0.5-1.0% (n = 9). When all the procedures were incorporated, including deproteinization and dilution of plasma, the intraassay CV was 2% at 2.5 mmol/L (n = 5) and 1% at 5.0 mmol/L (n = 5). The interassay CV for measuring bromide in plasma supernatants (initial plasma bromide concentration > 2.5 mmol/L) was 1%. Analytical recovery of bromide added to plasma was 99.1% +/- 2.5%. The new method is simpler and more reproducible than other spectrophotometric methods. Conditions for its automation are described.
منابع مشابه
A high-pressure liquid chromatographic-tandem mass spectrometric method for the determination of ethambutol in human plasma, bronchoalveolar lavage fluid, and alveolar cells.
A technique is presented for the specific and sensitive determination of ethambutol concentrations in plasma, bronchoalveolar lavage (BAL), and alveolar cells (AC) using a high-pressure liquid chromatographic (HPLC)-tandem mass spectrometric (MS-MS) method. The preparation of samples requires a deproteinization step with acetonitrile. The retention times for ethambutol, neostigmine bromide, and...
متن کاملValidation of HPLC-amperometric detection to measure serotonin in plasma, platelets, whole blood, and urine.
We describe an isocratic liquid-chromatographic method with amperometric detection for determination of serotonin by rapid sample preparation. Platelet-poor plasma and platelets were injected after a single deproteinization step with perchloric acid. Addition of sodium borohydride to whole blood avoids oxidation of serotonin during the deproteinization step without any chromatographic interfere...
متن کاملEnhancement of Frequency Domain Indices of Heart Rate Variability by Cholinergic Stimulation with Pyridostigmine Bromide
Pyridostigmine bromide (PB) is a reversible cholinesterase inhibitor. The aim of this study was to determine the effect of orally administration of single dose sustained-released tablet of pyridostigmine bromide (PBSR) on the frequency domain indices of heart rate variability (HRV). Thirty-two healthy young men were participated in this study. They were divided into 2 groups; the pyridostigmine...
متن کاملReal Life Experiences Using the Wrair Whole Blood and Pyridostigmine Assays
Walter Reed Army Institute of Research Whole Blood (WRAIR WB) cholinesterase assay rapidly determines the concentrations of both AChE and BChE in unprocessed whole blood, uses a minimally invasive blood sampling technique (finger prick), and is fully automated (using the Biomek 2000 robotic system). In human blood from volunteers given pyridostigmine bromide (30 mg single dose), RBC-AChE was ma...
متن کاملModification of the serum bromide assay for the measurement of extracellular fluid volume in small subjects.
Serum bromide has been used in the past to measure extracellular fluid volume in infants. In this report, a modification and refinement of a previously described spectrophotometric assay suitable for determining bromide levels in blood is presented. The assay involves sample deproteinization with perchloric acid followed by spectrophotometric analysis of the complexes formed by the reaction bet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1996