Towards proposition of a diagnostic reference level for mammographic examination in the greater Khorasan Province, Iran.

نویسندگان

  • M T Bahreyni Toossi
  • H Zare
  • Sh Bayani Roodi
  • M Hashemi
  • F Akbari
  • M Malekzadeh
چکیده

Although, over the past few years, the application of mammography has risen up sharply in Iran, very little, if any, has been reported of the extent of patient's dose from this type of imaging. The purpose of this study was to establish local diagnostic reference level (DRL) arising from mammography in the great Khorasan province of Iran. It is generally assumed that the glandular tissue is the most vulnerable type of breast tissue. Therefore, the mean glandular dose (MGD) has been widely accepted as the most appropriate dosimetric quantity to predict the risk of radiation-induced cancer. Literary, DRL for mammography is defined as the 75th percentile of MGD distribution. In Khorasan province, 7 out of 40 centres were randomly selected. In this work, 100 patients were studied. Thermoluminescence dosimeters have been used to measure entrance surface doses (ESDs). Since, it is difficult to directly measure MGD, Monte Carlo model-based conversion factors were utilised to conclude MGD from ESD. The results have revealed that patients dose is varied widely. The measured ESDs ranged from 0.74 to 19.81 mGy for the craniocaudal (CC) view and 1.20 to 25.79 mGy for the mediolateral oblique (MLO) view. The average MGDs per image were 0.88 and 1.11 mGy for CC and MLO views, respectively. Based on the internationally adopted definition, DRL arising from mammography tests for Khorasan is 1.33 mGy. Implementation of a dose reduction programme is suggested because of the large variations observed in patient MGD values. In this study, the DRL value is significantly lower than the corresponding values suggested by other researchers elsewhere.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Reference Level Arising from Dental Panoramic Radiography

Introduction The present work describes a study in which, based on patient dose measurements, thermoluminescent dosimeters were used to obtain the diagnostic reference level arising from panoramic radiography. Materials and Methods Ten panoramic units and a sample of 15 patients per X-ray unit were studied. Two thermoluminescent dosimeter chips were placed on the skin surface of selected organs...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...

متن کامل

Trend of hepatocellular carcinoma incidence after Bayesian correction for misclassified data in Iranian provinces

AIM To study the trend of hepatocellular carcinoma incidence after correcting the misclassification in registering cancer incidence across Iranian provinces in cancer registry data. METHODS Incidence data of hepatocellular carcinoma were extracted from Iranian annual of national cancer registration reports 2004 to 2008. A Bayesian method was implemented to estimate the rate of misclassificati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 155 1  شماره 

صفحات  -

تاریخ انتشار 2013