Evaluation of Osseointegration in Implants using Digital Orthopantomogram and Cone Beam Computed Tomography.

نویسندگان

  • Aastha Chopra
  • Amit A Mhapuskar
  • Swati Marathe
  • Shams U Nisa
  • Shameeka Thopte
  • Rashmi Saddiwal
چکیده

INTRODUCTION Accurate assessment of osseointegration in dental implants requires precise radiographic visualization of pathologic conditions as well as anatomical structures. The present study aimed to evaluate the formation of bony tissue (osseointegration) using digital orthopantomogram (OPG) and cone beam computed tomography (CBCT) immediately after implant insertion (within 7 days) and 3 months postinsertion. MATERIALS AND METHODS Twenty single-implant sites on mandi-bular posterior regions were selected on patients irrespective of their gender. Both digital OPG and CBCT were done within a week and again after 3 months of implant insertion surgery, using the same exposure parameters. RESULTS Three of the 20 implants were submerged and were excluded as the crestal bone height could not be measured. The participants were recalled for radiographic measurements after 3 months of implant placement. On an average, there was 0.03 mm of osseointegration at the apical portion after 3 months of implant insertion on digital OPG; 0.04 mm of osseointegration at the crestal bone height after 3 months on digital OPG; and 0.01 mm of osseointegration at the apical portion after 3 months on CBCT. No change or ≤0.02 mm of osseointegration at crestal bone height after 3 months on CBCT. CONCLUSION Both digital OPG and CBCT are significant for the assessment of osseointegration in implants, and hence, endow definite benefit for accurate assessment in terms of the success of the implant placement. CLINICAL SIGNIFICANCE However, CBCT is a better mode of evaluating dental implants but one should keep in mind that radiographic examination must be conducted to the benefit of the patient by application of the lowest achievable dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 17 11  شماره 

صفحات  -

تاریخ انتشار 2016