Correction: Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

نویسندگان

  • Giacomo Savini
  • Kenneth J. Hoffer
  • Piero Barboni
  • Nicole Balducci
  • Domenico Schiano-Lomoriello
  • Pietro Ducoli
چکیده

[This corrects the article DOI: 10.1371/journal.pone.0172634.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Part A: Biometry and Intraocular Lens Power Calculation

Formulas For Intraocular lens Power calculatIon Modern cataract surgery replaces the natural lens of the eye with an intraocular lens (IOL). After surgery, the optical system of the eye will consist of two major refractive elements, the cornea and the newly inserted IOL. This two-lens system is at the basis of IOL power calculation. To facilitate calculations, both the cornea and the IOL are co...

متن کامل

IOLMaster keratometry for the calculation of toric intraocular lens power and orientation

In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially fo...

متن کامل

Results of higher power toric intraocular lens implantation.

PURPOSE To evaluate the efficacy, predictability, and safety of coaxial microincision phacoemulsification and toric intraocular lens (IOL) implantation in eyes with high corneal astigmatism. SETTING Two eye clinics in Germany. DESIGN Case series. METHODS Routine cataract extraction using 2.2 mm coaxial phaco equipment and Acrysof toric IOL (3.00 to 6.00 diopters [D] cylinder) implantation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017