Evaluation of culture- and PCR-based detection methods for Escherichia coli O157:H7 in inoculated ground beeft.

نویسندگان

  • Terrance M Arthur
  • Joseph M Bosilevac
  • Xiangwu Nou
  • Mohammad Koohmaraie
چکیده

Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Viable But Non-Culturable State of Escherichia coli O157:H7 Using Reverse Transcription PCR

Background and Aims: Many bacteria including Escherichia coli may enter into a viable but non-culturable (VBNC) state under unfavorable stresses, which are unable to be detected by culture-based methods. In this study, the use of Reverse Transcription PCR (RT-PCR) for detection of VBNC state of E. coli O157:H7 was investigated. Materials and Methods:  Escherichia. coli O157:H7 was inoculated i...

متن کامل

Isolation of Escherichia coli O157:H7 from ground beef samples collected from beef markets, using conventional culture and polymerase chain reaction in Mashhad, northeastern Iran

  Escherichia coli O157:H7 is an important human pathogen causing haemorrhagic colitis, haemolyticuraemic syndrom and thrombotic thrombocytopenic purpura. In this study, 100 ground beef samples were collected randomly from beef markets in June 2004. For isolation of the bacteria, samples were firstly enriched in modified trypticase soy broth, followed by plating onto sorbitol MacConkey agar sup...

متن کامل

Identification of Escherichia coli O157: H7 from Slaughtered Beef in Mashhad Using Biochemical and Molecular Methods

Background and Aims: Escherichia coli O157:H7 is one of the main causes of transmitted diseases by food, including meat and meat products. The purpose of this study was to investigate the prevalence of E. coli O157:H7 contamination in Mashhad with the detection of rfbE gene. Materials and Methods: For this study, 148 slaughtered beef samples from Mashhad (spring to winter, 2018) were randomly ...

متن کامل

PCR detection of Escherichia coli O157:H7 directed from slaughtered cattle in Shiraz, Iran

  Escheric hia coli O157:H7 lives in the intestines of healthy cattle, and can contaminate meat during slaughtering pr actices . Detection of the low infectious dosage of bacterium requires a sensitive method. We developed polymerase chain reaction (PCR) assays to detect the gene Stx2 irrespective of the bacterial serotype. In this study, the detection limit of the PCR protocol in detecting Stx...

متن کامل

Comparison of the BAX for screening/E. coli O157:H7 method with conventional methods for detection of extremely low levels of Escherichia coli O157:H7 in ground beef.

Escherichia coli O157:H7 is an important food-borne pathogen. Often E. coli O157:H7 is difficult to detect, because it is present sporadically at very low levels together with very high levels of competitor organisms which can be difficult to distinguish phenotypically. Cultural methods are time-consuming and give variable results in the detection of E. coli O157:H7. This study examined the per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food protection

دوره 68 8  شماره 

صفحات  -

تاریخ انتشار 2005