Advanced Doubly Fed Induction Machine Rotor Fault Diagnosis Based on Wavelet Analysis in Closed-Loop Operation Under Time–varying Condition
نویسندگان
چکیده
This paper introduces a new diagnostic technique for the detection of incipient electrical rotor faults in doubly fed induction Machine (DFIM) for wind power systems. In the considered application, the rotor is supplied by a static converter for the control of active and reactive power flows from the generator to the electrical grid. A new diagnostic method based on the rotor modulating signals pre-processing by Frequency Sliding (FS) and Discrete Wavelet Transform (DWT) thereby is here proposed to detect rotor faults dynamically over time. Experimental and simulation results demonstrate the effectiveness of the proposed approach under time-varying conditions.
منابع مشابه
A Novel Algorithm for Rotor Speed Estimation of DFIGs Using Machine Active Power based MRAS Observer
This paper presents a new algorithm based on Model Reference Adaptive System (MRAS) and its stability analysis for sensorless control of Doubly-Fed Induction Generators (DFIGs). The reference and adjustable models of the suggested observer are based on the active power of the machine. A hysteresis block is used in the structure of the adaptation mechanism, and the stability analysis is performe...
متن کاملSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کاملDiagnosis of Induction Motor Rotor Fault through Discrete Wavelet Transform Applied to Residual Current
Induction motors are critical components in industrial processes since their failure usually lead to an unexpected interruption at the industrial plant. The condition monitoring of the induction motors have been a challenging topic for many electrical machine researchers. Indeed, the effectiveness of the fault diagnosis and prognosis techniques depends very much on the quality of the fault feat...
متن کاملLarge Disturbance Stability Analysis of Wind Turbine Implemented with DFIG
As one of the most promising Distributed Generation (DG) sources, wind power technology has been widely developed in recent years. Doubly fed induction generator (DFIG) is currently employed as one of the most common topologies for wind turbine generators (WTGs). This generator operates as a synchronous/asynchronous hybrid generators. Therefore, it is necessary to power engineers find understan...
متن کاملCombined Use of Sensitivity Analysis and Hybrid Wavelet-PSO- ANFIS to Improve Dynamic Performance of DFIG-Based Wind Generation
In the past few decades, increasing growth of wind power plants causes different problems for the power quality in the grid. Normal and transient impacts of these units on the power grid clearly indicate the need to improve the quality of the electricity generated by them in the design of such systems. Improving the efficiency of the large-scale wind system is dependent on the control parameter...
متن کامل