Foot loading in amputee stance.

نویسندگان

  • M Lord
  • D M Smith
چکیده

A survey has been carried out to establish information on foot loading in amputee stance. The parameters measured are percentage body weight and the positions of the centres of pressure under each foot. The data was collected in a clinical environment by the use of a Double Video Forceplate (DVF), a tool developed at the Bioengineering Centre. The objective of the survey is to provide background information for the use of the DVF in static alignment of lower-limb prostheses. Results are presented from a number of patients attending the Roehampton Walking Training School, and for a small group of patients attending the Bioengineering Centre for delivery of an experimental below-knee prosthesis. Scattergrams and averaged results provide normative data which can assist in interpretation of DVF displays during individual alignment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR)...

متن کامل

Altering prosthetic foot stiffness influences foot and muscle function during below-knee amputee walking: a modeling and simulation analysis.

Most prosthetic feet are designed to improve amputee gait by storing and releasing elastic energy during stance. However, how prosthetic foot stiffness influences muscle and foot function is unclear. Identifying these relationships would provide quantitative rationale for prosthetic foot prescription that may lead to improved amputee gait. The purpose of this study was to identify the influence...

متن کامل

The effects of prosthetic ankle dorsiflexion and energy return on below-knee amputee leg loading.

BACKGROUND Prosthetic devices are intended to return lower limb amputees to their pre-amputation functional status. However, prosthetic devices designed for unilateral below-knee amputees have yet to completely restore the biomechanical functions normally provided by the ankle muscles, leading to gait asymmetries and increased reliance on their intact leg. In an effort to improve amputee gait, ...

متن کامل

Finite element modelling of an energy-storing prosthetic foot during the stance phase of transtibial amputee gait.

Energy-storing prosthetic feet are designed to store energy during mid-stance motion and to recover it during late-stance motion. Gait analysis is the most commonly used method to characterize prosthetic foot behaviour during walking. In using this method, however, the foot is generally modelled as a rigid body. Therefore, it does not take into account the ability of the foot to deform. However...

متن کامل

Balance in lower limb child amputees.

Postural stability of five unilateral above-knee amputee children was measured when wearing the SACH and the experimental Child Amputee Prosthetic Project (CAPP) prosthetic foot. Excursions of the centre of pressure of the supportive forces were recorded via force platform during sustained weight-shifting forward, backward, left, right, and during normal standing. Visual proprioception effects ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 1984