Cardiac pacing in Northern Ireland 1979-1988.
نویسنده
چکیده
The implantation rate of cardiac pacemakers in Northern Ireland rose from 55.8 per million population in 1979 to over 180 per million in 1988, with the emergence of a second pacemaker implantation centre. However, the implantation rate in Northern Ireland remains less than that of many other countries. Over the period complete heart block fell as an indication from 45% to 34% and sinus node disease rose from 16% to 28%. Symptoms necessitating pacing remained unchanged, syncope being the most common. Ventricular demand pacemakers constituted a lower proportion of implants than anywhere else in the world and more atrial demand and dual chamber pacemakers were implanted than in most other countries. Insufficient patients are being referred for pacing in Northern Ireland but a high proportion of those who are referred receive modern sophisticated pacemakers.
منابع مشابه
Cystic fibrosis in Northern Ireland.
In a retrospective study of cystic fibrosis in Northern Ireland for 1961 to 1971, the incidence was 1 in 1857 livebirths, which is comparable to figures from Great Britain and the Republic of Ireland.
متن کاملSex ratio of births in Ireland in 1978.
DATA AND METHODS The data for Northern Ireland for the years 1922-1978 were obtained from the Annual Reports of the Registrar General for Northern Ireland'. For the years 1913 to 1921 the data were obtained from the Second Annual Report of the Registrar General (Northern Ireland), 19232. Provisional data for 19793 were provided by the General Register Office for Northern Ireland. The data for t...
متن کاملDistribution of properdin factor B and glyoxalase I (further genetic markers) in Northern Ireland
The normal distribution in Northern Ireland of the genetic markers properdin factor B (Bf) and glyoxalase I (GLO) are described. These markers are available for comparison in disease studies, family studies and paternity studies.
متن کاملComparison of central nervous system malformations in spontaneous absortions in Northern Ireland and south-east England.
A study of 1140 pregnancies ending in spontaneous abortion disclosed a central nervous system (CNS) malformation in 4.9% of all complete conceptuses. Life-table analysis suggested that the incidence of CNS malformations is 16/1000 at the beginning of the eighth week of gestation. It was also estimated that only one-fifth of these infants are born alive, 41% being aborted spontaneously and 38% s...
متن کاملSuccessful transcutaneous external pacing for asystole following cardiac arrest.
We report a case of successful transcutaneous external pacing for out of hospital cardiac arrest causing asystole.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Ulster Medical Journal
دوره 59 شماره
صفحات -
تاریخ انتشار 1990