Direct measurement of the proton magnetic moment.

نویسندگان

  • J DiSciacca
  • G Gabrielse
چکیده

The proton magnetic moment in nuclear magnetons is measured to be μ(p)/μ(N) ≡ g/2 = 2.792 846 ± 0.000 007, a 2.5 parts per million uncertainty. The direct determination, using a single proton in a Penning trap, demonstrates the first method that should work as well with an antiproton (p) as with a proton (p). This opens the way to measuring the p magnetic moment (whose uncertainty has essentially not been reduced for 20 years) at least 10(3) times more precisely.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing an approprate solenoid and magnetic field for the HZDR laser-driven beamline

Nowadays, due to the high costs and large dimensions of the conventional proton accelerators, other optimal methods for producing the proton beam have been studied. Using of Laser-driven proton accelerators is one of the important and new methods. In laser-driven ion acceleration, a highly ultra-intense laser pulse interacts with solid density targets and will create a plasma media that will ac...

متن کامل

Observation of spin flips with a single trapped proton.

Radio-frequency induced spin transitions of one individual proton are observed. The spin quantum jumps are detected via the continuous Stern-Gerlach effect, which is used in an experiment with a single proton stored in a cryogenic Penning trap. This is an important milestone towards a direct high-precision measurement of the magnetic moment of the proton and a new test of the matter-antimatter ...

متن کامل

Measurement of the (anti)proton g-factor - Status of the experiment

The measurement and comparison of the magnetic moment (or g-factor) of the proton and antiproton provide a stringent experimental test of the CPT-theorem in the baryonic sector [1]. We set up an experiment for the first selfcontained and direct high-precision measurement of the gfactor of a single isolated proton stored in a Penning trap [2]. In previous experiments the g-factor was determined ...

متن کامل

Antiproton magnetic moment determined from the HFS of pHe

We report a determination of the antiproton magnetic moment, measured in a three-body system, independent of previous experiments. We present results from a systematic study of the hyperfine (HF) structure of antiprotonic helium where we have achieved a precision more than a factor of 10 better than our first measurement. A comparison between the experimental results and three-body quantum elec...

متن کامل

Measurement of the X Magnetic Moment Using the X = ne v and X = - n ~ Decay Modes

We have used the spin-precession technique to measure the X magnetic moment (p, x). A X beam with a polarization of 22'/0 was produced by a 400-GeV proton beam striking a Cu target at nominal production angles of +3 mrad. We simultaneously recorded 21000 X ne v decays and 650000 X n~ decays at X beam momenta of 253 and 308 GeV/c. We find p, x = —1.166 +0.014 +0.010 nuclear magnetons, where the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 108 15  شماره 

صفحات  -

تاریخ انتشار 2012