Decreased Lamina Cribrosa Beam Thickness and Pore Diameter Relative to Distance From the Central Retinal Vessel Trunk

نویسندگان

  • Bo Wang
  • Katie A. Lucy
  • Joel S. Schuman
  • Ian A. Sigal
  • Richard A. Bilonick
  • Larry Kagemann
  • Tigran Kostanyan
  • Chen Lu
  • Jonathan Liu
  • Ireneusz Grulkowski
  • James G. Fujimoto
  • Hiroshi Ishikawa
  • Gadi Wollstein
چکیده

PURPOSE To investigate how the lamina cribrosa (LC) microstructure changes with distance from the central retinal vessel trunk (CRVT), and to determine how this change differs in glaucoma. METHODS One hundred nineteen eyes (40 healthy, 29 glaucoma suspect, and 50 glaucoma) of 105 subjects were imaged using swept-source optical coherence tomography (OCT). The CRVT was manually delineated at the level of the anterior LC surface. A line was fit to the distribution of LC microstructural parameters and distance from CRVT to measure the gradient (change in LC microstructure per distance from the CRVT) and intercept (LC microstructure near the CRVT). A linear mixed-effects model was used to determine the effect of diagnosis on the gradient and intercept of the LC microstructure with distance from the CRVT. A Kolmogorov-Smirnov test was applied to determine the difference in distribution between the diagnostic categories. RESULTS The percent of visible LC in all scans was 26 ± 7%. Beam thickness and pore diameter decreased with distance from the CRVT. Glaucoma eyes had a larger decrease in beam thickness (-1.132 ± 0.503 μm, P = 0.028) and pore diameter (-0.913 ± 0.259 μm, P = 0.001) compared with healthy controls per 100 μm from the CRVT. Glaucoma eyes showed increased variability in both beam thickness and pore diameter relative to the distance from the CRVT compared with healthy eyes (P < 0.05). CONCLUSIONS These findings results demonstrate the importance of considering the anatomical location of CRVT in the assessment of the LC, as there is a relationship between the distance from the CRVT and the LC microstructure, which differs between healthy and glaucoma eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morphometry of the human lamina cribrosa surface.

The lamina cribrosa is a sieve-like perforation in the posterior part of the sclera, that allows passage of the retinal ganglion cell axons and central retinal vessels and preserves a pressure gradient between the intraocular and extraocular space. It has been termed the primary site of glaucomatous damage to the optic nerve. Using electron microscopy, the authors morphometrically evaluated the...

متن کامل

In vivo lamina cribrosa micro-architecture in healthy and glaucomatous eyes as assessed by optical coherence tomography.

PURPOSE The lamina cribrosa (LC) is a prime location of glaucomatous damage. The purpose of this study was to compare LC 3-dimensional micro-architecture between healthy and glaucomatous eyes in vivo by using optical coherence tomography (OCT). METHODS Sixty-eight eyes (19 healthy and 49 glaucomatous) from 47 subjects were scanned in a 3.5 × 3.5 × 3.64-mm volume (400 × 400 × 896 pixels) at th...

متن کامل

Finite element modeling of optic nerve head biomechanics.

PURPOSE Biomechanical factors have been implicated in the development of glaucomatous optic neuropathy, particularly at the level of the lamina cribrosa. The goal of this study was to characterize the biomechanics of the optic nerve head using computer modeling techniques. METHODS Several models of the optic nerve head tissues (pre- and postlaminar neural tissue, lamina cribrosa, central reti...

متن کامل

Reproducibility of In-Vivo OCT Measured Three-Dimensional Human Lamina Cribrosa Microarchitecture

PURPOSE To determine the reproducibility of automated segmentation of the three-dimensional (3D) lamina cribrosa (LC) microarchitecture scanned in-vivo using optical coherence tomography (OCT). METHODS Thirty-nine eyes (8 healthy, 19 glaucoma suspects and 12 glaucoma) from 49 subjects were scanned twice using swept-source (SS-) OCT in a 3.5×3.5×3.64 mm (400×400×896 pixels) volume centered on ...

متن کامل

In vivo three-dimensional characterization of the healthy human lamina cribrosa with adaptive optics spectral-domain optical coherence tomography.

PURPOSE To characterize the in vivo three-dimensional (3D) lamina cribrosa (LC) microarchitecture of healthy eyes using adaptive optics spectral-domain optical coherence tomography (AO-SDOCT). METHODS A multimodal retinal imaging system with a light source centered at 1050 nm and AO confocal scanning laser ophthalmoscopy was used in this study. One randomly selected eye from 18 healthy subjec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016