Displacement of a Fixed Versus Adjustable Suspensory Fixation Device for Anterior Cruciate Ligament Reconstruction

نویسنده

  • Mike Perriello
چکیده

Suspensory fi xation devices in anatomic anterior cruciate ligament (ACL) reconstruction commonly feature a button that rests on the cortex of the femur, and a loop that holds the graft in position until healing can occur. While this loop can be closed and fi xed in length, some contemporary designs feature a loop that is adjustable. The purpose of this study was to assess the displacement of the fi xed ENDOBUTTONTM CL ULTRA (Smith & Nephew, Inc., Andover, MA, USA) and TightRope® (Arthrex, Inc., Naples, FL, USA) fi xation devices. All loop samples were securely fi xed to a metal plate and axial loading apparatus. Next, a zero to 60N static load was applied to each sample a total of ten times. Following completion of the loading regimen, loop displacement and fi nal distance were measured. Results of this study demonstrated signifi cantly less displacement for the ENDOBUTTON CL ULTRA device vs the TightRope device (0.58mm versus 9.95mm; p < 0.05). Furthermore, the mean distance from the button to the top of the hook for the devices was 8.93mm (ENDOBUTTON) and 14.63mm (TightRope), respectively (p < 0.05). The results of this study suggest that the adjustable TightRope loop can slip and elongate under load after it has been adjusted to its minimum length. It also suggests that ENDOBUTTON CL Ultra may allow for more graft in the femoral tunnel following ACL reconstruction. Vol 03, No 7 July 2012

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical properties of suspensory fixation devices for anterior cruciate ligament reconstruction: comparison of the fixed-length loop device versus the adjustable-length loop device.

BACKGROUND No definite consensus has been reached regarding the optimal technique for graft fixation to the femur in an anterior cruciate ligament reconstruction. The purpose of this study was to evaluate the mechanical strength of two cortical suspension devices which were the TightRope (TR), a new adjustable-length loop device, and the EndoButton (EB), a well-established fixed-length loop dev...

متن کامل

Comparing outcomes of reconstruction of anterior cruciate ligament rupture with fixed loop and adjustable loop

Background: Recently, the surgical methods are used in patients with anterior cruciate ligament rupture and have been associated with successful results. There are different results in the term of using of the surgical methods for anterior cruciate ligament that often is associated with some complications such as infection, static laxity, remaining the pain, need to recurrence surgery, and limi...

متن کامل

Graft Retensioning Technique Using an Adjustable-Loop Fixation Device in Arthroscopic Anterior Cruciate Ligament Reconstruction

Anterior cruciate ligament (ACL) tears are an unfortunate and devastating injury in the athletic patient. Surgical reconstruction of the ACL with a taut graft construct is necessary to restore knee stability and help expedite the patient's return to an active lifestyle. Arthroscopy-assisted ACL reconstruction can be a technically involved procedure, where strong fixation limits graft motion to ...

متن کامل

A Technique of Superficial Medial Collateral Ligament Reconstruction Using an Adjustable-Loop Suspensory Fixation Device.

This report describes superficial medial collateral ligament reconstruction of the knee using a novel method of graft fixation with the ACL Tightrope RT (Arthrex, Naples, FL). After tibial fixation with either a standard interference screw or staple, femoral fixation of the semitendinosus tendon is performed with the adjustable-loop suspensory fixation device, which allows for both initial graf...

متن کامل

A comparison of functional outcome between bioabsorbable interference screw and endobutton fixation on femur in arthroscopic anterior cruciate Ligament reconstruction

Introduction: Arthroscopic Anterior Cruciate Ligament [ACL] reconstruction is very commonly done procedure in recent times {1}. The graft fixation methods vary from aperture fixation [Interference screws] to suspensory fixation methods [Endobutton]. This is a Prospective non randomised clinical study of arthroscopic ACL reconstruction comparing the functional results between aperture fixation a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012