Double transseptal puncture guided by real-time three-dimensional transoesophageal echocardiography during atrial fibrillation ablation.

نویسندگان

  • Gian Battista Chierchia
  • Guy Van Camp
  • Andrea Sarkozy
  • Carlo de Asmundis
  • Pedro Brugada
چکیده

A 65-year-old man was admitted to our centre because of recurrent drug-resistant episodes of paroxysmal atrial fibrillation, for pulmonary vein radiofrequency catheter ablation. Double transseptal (TS) puncture was performed under realtime three-dimensional transoesophageal echocardiography (RT 3D TEE) guidance. We started by placing a quadripolar catheter in the coronary sinus and a Pigtail catheter in the aortic root as fluoroscopic landmarks. We then positioned the first 8 F TS sheath (St Jude Medical, St Paul, MN, USA) in the superior vena cava. Under echo and biplane fluoroscopic guidance in anterio-posterior and left-lateral projections, the whole system was withdrawn and placed in the fossa ovalis keeping the needle hub arrow pointing between 3.30 and 5 o’clock position. The position was confirmed by RT 3D TEE imaging (Philips i 33 ultrasound system, X7-2t TEE probe, Philips Ultrasound, Bothell, WA 98021-8431, USA) by applying a slight pressure to obtain ‘tenting’ of the fossa ovalis (Figure 1A). We then performed the puncture of the septum with the needle under low flow saline flushing (Figure 1B). A short injection of contrast was used for further confirmation of TS puncture. Right after this, we advanced the sheath-dilator assembly over the needle. We then performed a second puncture under echocardiographic guidance using the same approach as described earlier (Figure 1C). In this setting, RT 3D TEE was of upmost importance showing not only the fossa ovalis, but also the orientation of the needle. This is due to its visual 3D information. We could push the needle through in total safety, minimizing the risk of complications. Figure 1D shows a fluoroscopic image in an anteroposterior projection of the second TS puncture including the landmarks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation.

AIMS Transseptal (TS) puncture during atrial fibrillation (AF) ablation is a relatively safe procedure in experienced hands. However, major and minor complications cannot be completely ruled out. Real-time three-dimensional transeosophageal echocardiography (RT 3D TEE) is a novel imaging technology that permits direct visualization of the fossa ovalis in a 3D perspective, thereby sensibly lower...

متن کامل

Intracardiac Echocardiography in Catheter Ablation for Atrial Fibrillation: It Is Better to See What You Are Doing?

Current advanced technology allows the accurate three-dimensional reconstruction of cardiac structures using multiple images from two-dimensional intracardiac echocardiography (ICE). This technology is applicable to atrial fibrillation (AF) ablation and provides real-time anatomical information on relevant atrial structures and myocardial thickness as well as suitable sites for transseptal punc...

متن کامل

Cryoballoon ablation for paroxysmal atrial fibrillation in the presence of an Amplatzer Septal Occluder device

Cryoballoon ablation of the pulmonary veins (CAPV) has been demonstrated to be non-inferior to radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AFib). As CAPV requires a larger transseptal sheath than RF ablation, it can be challenging in the presence of an AmplatzerTM Septal Occluder (ASO) device. Real-time three-dimensional transesophageal echocardiography (RT3DTEE) provides e...

متن کامل

Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study.

AIMS Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. The aim of the present study was to assess the feasibility, advantages, and safety of RT 3D TEE in...

متن کامل

Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2008