Narrow-Diameter Implant versus Lateral Bone Augmentation: What are the Evidences?

نویسنده

  • Moustapha Saad
چکیده

For optimizing functional and esthetic implant therapy results, sufficient bone amount is required at the reception site. A reduced buccolingual ridge dimension may not allow the placement of a standard-diameter implant without the risk of implant thread exposure. In such situations, lateral bone augmentation procedures can be performed that would allow a restorative-driven placement of standard-diameter implants. Conversely, the use of narrow-diameter implants (diameter ≤ 3.5mm) could be another predictable solution to avoid any invasive surgical management. The aim of this review is to analyze the survival rate of narrow-diameter implants as well as the effectiveness of different techniques for lateral bone augmentation in improving implant clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of a Congenitally Missing Lateral Incisor with Orthodontics, Bone Grafting (a New Method) and Single-Tooth Implant: A Case Report

Careful treatment planning, space management, augmentation of bone and attention to the details of implant surgical and prosthetic techniques are important factors when treating anterior maxilla specially replacement of missing teeth. This case report addresses a chair-side ridge augmentation procedure using autograft bone harvested with trephine drills and placed without using screws and the f...

متن کامل

The Use of Narrow Diameter Implants in the Molar Area

Implant rehabilitations in the posterior jaw are influenced by many factors such as the condition of the remaining teeth, the force factors related to the patient, the quality of the bone, the maintenance of the hygiene, the limited bone height, the type and extent of edentulism, and the nature of the opposing arch. The gold standard is to place a regular diameter implant (>3.7 mm) or a wide on...

متن کامل

Narrow implants (2.75 and 3.25 mm diameter) supporting a fixed splinted prostheses in posterior regions of mandible: one-year results from a prospective cohort study

BACKGROUND Can multiple splinted narrow-diameter implants be used as definitive implants in patients with insufficient bone ridge thickness in posterior regions of the mandible? With this aim, we evaluated their outcomes in this set up to 1 year after loading. METHODS Forty-two patients with a mean age of 61.3 years old (range 49-73) in need of fixed prosthetic implant-supported rehabilitatio...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Capsular Weakness around Breast Implant: A Non-Recognized Complication

Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013