The origins of the sinus node pacemaker complex in man: demonstration of dominant and subsidiary foci.

نویسندگان

  • J A Gomes
  • S L Winters
چکیده

To test the hypothesis that the human sinus node is capable of demonstrating multiple sites of impulse generation, we assessed spontaneous shifts in the sinus node pacemaker complex, and shifts after overdrive atrial pacing, premature atrial stimulation and carotid sinus massage. A total of 24 patients aged 59 +/- 15 years (mean +/- SD) in whom stable sinus node electrograms were obtained were selected for the study. Ten of the 24 patients had sick sinus syndrome, whereas 14 had no sinus node dysfunction. All 24 patients had atrial pacing at cycle lengths of 1,000 to 300 ms; 9 patients had premature atrial stimulation and 12 had carotid sinus massage. Shifts in the sinus node pacemaker complex occurred spontaneously in 4 (17%) of the 24 patients; after atrial pacing at cycle lengths of 800 to 300 ms (mean 387 +/- 92) in 15 (63%) of 24 patients; after premature atrial stimulation at one or more coupling intervals in 5 (56%) of 9 patients and during carotid sinus massage in 9 (75%) of 12 patients. Shifts in the sinus node pacemaker complex lasted one to six beats and returned to the original site within two to seven beats. Spontaneous shifts in the sinus node pacemaker complex occurred in 3 of 14 patients without sick sinus syndrome and were induced in 6 (60%) of 10 patients with sick sinus syndrome and 11 (79%) of 14 patients without sick sinus syndrome. Shifts in sinus node pacemaker complex were characterized by loss of primary negativity, change in P wave morphology, significant (p less than 0.001) prolongation of sinoatrial interval and sinus cycle length.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patients with Dysfunction of the Sinus Node*

Automaticity (postpacing impulse recovery time) of the sinus node or subsidiary pacemakers (or both) was determined by intracardiac recordings and atrial overdrive pacing in three patients with disease of the sinus node. Their electrocardiographic manifestations included sinus bradycardia, sinoatrial block, sinus arrest, afrioventricular junctional rhythm, and atrioventricular dissociation. One...

متن کامل

Acceleration of Sinus Rhythm During Slow-rate

We evaluated the effects of slow-rate atrial pacing on impulse formation of the sinus node in 13 isolated rabbit right atria using the microelectrode technique. After the spread of activation was mapped to determine true sinoatrial conduction time (SACT) (38 ± 16 msec [± SD]), the atrium was paced for eight beats at constant intervals slightly shorter than spontaneous cycle length in steps of 1...

متن کامل

BRIEF REVIEWS The Relationship among Cardiac Pacemakers Overdrive Suppression

THE RELATIONSHIP among cardiac pacemakers is characterized by the fact that usually one pacemaker is dominant and all the others are subsidiary. The sinoatrial node acts as the dominant pacemaker and all other pacemaker tissues are discharged by a conducted impulse before their diastolic depolarization can attain threshold. These pacemakers are called subsidiary to emphasize the fact that under...

متن کامل

Overdrive Suppression

THE RELATIONSHIP among cardiac pacemakers is characterized by the fact that usually one pacemaker is dominant and all the others are subsidiary. The sinoatrial node acts as the dominant pacemaker and all other pacemaker tissues are discharged by a conducted impulse before their diastolic depolarization can attain threshold. These pacemakers are called subsidiary to emphasize the fact that under...

متن کامل

تفاوتهای ناحیه ای در نقش جریان یونی if در تولید پتانسیلهای پیس میکری سلولهای گره سینوسی – دهلیزی دست نخورده و سالم قلب خرگوش

Background: The sinoatrial (SA) node is not a uniform tissue in terms of its histology and electrophysiology. The regional differences in action potential configuration are well known, for which the difference on ionic currents underlying the regional differences in electrical activity is the most probable cause. The ionic current "if" is though to play a major role in SA node for pace maker sl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 1987