Navigator gated flow sensitive gradient echo sequence for quantification of aortic valve regurgitation

نویسندگان

  • Jonathan Nadjiri
  • Caroline Sonne
  • Eva Hendrich
  • Albrecht Will
  • Cornelia Pankalla
  • Stefan Martinoff
  • Martin Hadamitzky
چکیده

Background Exact quantification of aortic valve regurgitation is a challenge. Patients are typically asymptomatic and echocardiography is unreliable in certain conditions, particularly in eccentric regurgitation jets. Cardiac magnetic resonance (CMR) is a valuable alternative in this situation, but the use of conventional sequences without respiration correction is limited by motion artifacts and long acquisition times caused by necessary signal averaging. Novel navigator gated flow sensitive gradient echo sequence avoid motion artifacts caused by respiration and in addition allow for a higher temporal resolution eventually leading to more reliable results. Methods On 31 patients with varying degrees of aortic regurgitation we performed both standard (StdSeq) and navigator gated (NavSeq) flow sensitive gradient echo sequences. Primary parameter was the regurgitation fraction defined as the quotient of anterograde and retrograde flow over a cross section of the ascendent aorta just above the maximal excursion of the aortic leaflets. Since a gold standard for quantification of aortic regurgitation is missing, we correlated these values with the enddiastolic volume of the left ventricle (LVEDV) assessed by a contiguous stack short axis cine-SSFP sequences. This parameter is directly influenced by the regurgitant volume. For comparison we

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging strategies of coarctation repairs

Background Coarctation is a common cardiovascular lesion accounting for 5 7% of all congenital heart disease. Without appropriate treatment complications are common and up to 90% of patients with uncorrected coarctation die by the age of 60. After repair close follow-up of patients is recommended. Recognised complications may include residual or recurrent coarctation and aneurysm formation. Fol...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Quantification of valvar regurgitation by cardiac gated pool imaging.

Fifty patients with aortic and/or mitral regurgitation underwent gated pool imaging and cardiac catheterisation to quantify the severity of valvar regurgitation. Gated pool imaging was performed in the left anterior oblique projection and an estimate of regurgitant fraction derived by comparison of the left ventricular to right ventricular stroke volume expressed as a ratio. In 17 normal subjec...

متن کامل

Mitral valve blood flow quantification by 7D phase contrast SSFP - a feasibility study

Purpose: to assess the feasibility of a new 7D PC-SSFP sequence for single acquisition mitral regurgitation volume quantification. Materials and Methods: The 7D PC-SSFP sequence implementation is based on a regular 3D balanced SSFP gradient scheme with velocity encoding. Accuracy of velocity quantification was confirmed using a flow-phantom. Mitral volume flow was measured in ten healthy subjec...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014