Pediatric Patients and Tonometers
نویسندگان
چکیده
247 ©Copyright 2017 by Turkish Ophthalmological Association Turkish Journal of Ophthalmology, published by Galenos Publishing House. Dear Editor, The recent publication on “Pediatric Patients and Tonometers” is interesting.1 Eraslan et al.1 concluded that “Because Tono-Pen (TP) measurements were lower than Goldmann applanation tonometer (GAT) measurements and non-contact tonometer measurements were higher than GAT measurements, patient follow-ups, treatment strategies, and surgery plans must be organized taking these differences into consideration”. The results in this report are similar to a recent report by Galgauskas et al.2 In fact, the use of different kinds of tonometer can result in different measures values and this has to be kept in mind by practitioners. The correlation study can be useful for checking the variability of the tool. Nevertheless, there are some concerns that should be addressed. First, the lack of a gold standard for the comparative study is a big issue for further discussion. At present, we can only perform the inter-tool agreement check but there is no gold standard for checking the accuracy of the measurement. Second, for each tool the within-day and between-day precision of the tool should also be checked. Finally, the calibration error of the tool should be regularly checked since it can contribute to incorrect measurement results.3 In the present report by Eraslan et al.,1 there is no error checking as well.
منابع مشابه
Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملTonometer calibration in Brasília, Brazil.
PURPOSE To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration...
متن کاملComparison of Perkins, Tono-Pen and Schiøtz tonometers in paediatric patients under general anaesthesia.
This cross-sectional study aimed to investigate if the Tono-Pen, Schiøtz and Perkins tonometers could be used interchangeably in general practice for measuring elevated intraocular pressure. A total of 74 eyes of 37 paediatric patients under general anaesthesia were checked with all 3 tonometers. All of the tonometers gave significantly different measurements from each other. However, with a me...
متن کاملComparison of Intraocular Pressure Measurements in Healthy Pediatric Patients using Three Types of Tonometers
OBJECTIVES This study aimed to compare intraocular pressure (IOP) measurements in healthy pediatric patients using three types of tonometers. MATERIALS AND METHODS Seventy-eight eyes of 78 patients under the age of 18 who underwent a routine ophthalmologic examination were included in the study. IOP was measured using Tono-Pen (TP) tonometry, Goldmann applanation tonometry (GAT), and non-cont...
متن کاملComparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and goldmann applanation tonometry
PURPOSE Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100) with Goldmann applanation tonometry (GAT). METHODS This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP) was measured by GAT and the PT100...