A radioimmunoassay (RIA) has been developed using 125I-amikacin. Amikacin was iodinated by a modified BOLTON and HUNTER method. Dextran-charcoal was used to separate bound from free drug. The standard curve was linear on a logit-log plot in the range of 0.5 ng to 4 ng amikacin per tube. There was no cross-reactivity of amikacin antisera to the amino-glycosides gentamicin, tobramycin, netilmicin, and sisomicin but a 70% cross-reaction was observed with kanamycin, the compound from which amikacin is synthetically derived. Correlation of the RIA with a microbioassay for the determination of serum amikacin levels in 18 patient samples was excellent (r = 0.94). This new RIA technique is more sensitive, rapid, versatile, and less costly than the RIA using 3H-amikacin, and is far more sensitive and faster than microbioassay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of radioimmunoassay technique for determination of antigen concentration in different cells with a new monoclonal antibody [Persian]

Introduction: Binding a monoclonal antibody to tumor associated antigens is an effective method for cancer therapy because these agents can specifically target malignant cells, in fact monoclonal antibodies are effective agents for diagnosis, grading and treatment of different kinds of cancers. Methods: In this research, a new monoclonal antibody against colon cancer cells was prepared an...

متن کامل

Measurement of three aminoglycosiee antibiotics with a single radioimmunoassay system.

A versatile radioimmunoassay procedure has been developed to specifically assay gentamicin, tobramycin, or amikacin. Iodinated derivatives of these three antibiotics were prepared by a modified Bolton and Hunter procedure. A single reagent system composed of a pool of three very specific antisera was used in the procedure. The antisera combination did not alter the specificity of the procedure....

متن کامل

Comparison of the reversed passive hemagglutination with radioimmunoassay methods for hepatitis B antigen.

Radioimmunoassay for the detection of hepatitis B antigen has been accepted in many diagnostic laboratories now. The question of nonspecific positives has always been a matter of controversy. Two improved radioimmunoassay tests, namely Ausria II-125 by Abbott Laboratories and a radioimmunoassay method by Connaught Laboratories Limited (Hebria), were compared with the original Ausria 125I. Inclu...

متن کامل

Radioimmunoassay for bupropion in human plasma: comparison of tritiated and iodinated radioligands.

We evaluated the potential usefulness of 125I-labeled p-hydroxybupropion in a direct radioimmunoassay for bupropion in human plasma as compared with a currently used [3H]bupropion dextran-coated charcoal method. In both radioimmunoassay methods succinoylpropylbupropion antiserum was used that was highly specific for unchanged drug, cross reactivities with known bupropion metabolites being less ...

متن کامل

Assessment of epidermal growth factor receptor status in glioblastomas

Objective(s): Our previous study showed that a newly designed tracer radioiodinated 6-(3-morpholinopropoxy)-7-ethoxy-4-(3'-iodophenoxy)quinazoline ([125I]PYK) is promising for the evaluation of the epidermal growth factor receptor (EGFR) status and prediction of gefitinib treatment of non-small cell lung cancer. EGFR is over-expressed and mutated also in glioblastoma. In the present study, the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of antibiotics

دوره 29 8  شماره 

صفحات  -

تاریخ انتشار 1976