MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences.

نویسندگان

  • M L Gawne-Cain
  • J I O'Riordan
  • A Coles
  • B Newell
  • A J Thompson
  • D H Miller
چکیده

OBJECTIVES To assess whether multiple sclerosis lesion volume measurements derived using the fast fluid attenuated inversion recovery (fFLAIR) sequence show better reproducibility or correlation with disability than those derived using the conventional spin echo (CSE) sequence. METHODS Part I: twenty five patients with multiple sclerosis were scanned with CSE, fast spin echo (FSE), and fFLAIR. Lesion volume was determined twice for each sequence using a local threshold segmentation technique. Part II: fifty six patients with multiple sclerosis were scanned with CSE and fFLAIR. Total and regional brain lesion volumes were compared with the Kurtzke extended disability scale (EDSS) and functional systems scores (FSS). RESULTS Part I: analysis times were significantly longer for CSE than for FSE or fFLAIR. There was no significant difference in the reproducibility of the three sequences. Part II: total lesion volumes were similar but posterior fossa lesion volumes were significantly greater for CSE and subcortical lesion volumes significantly greater for fFLAIR. There was a significant correlation between total volume and EDSS with both sequences (CSE r=0.49; fFLAIR r=0.44). Correlations for the two sequences showed minor differences when anatomical region and FSS were considered separately. CONCLUSIONS CSE, FSE, and fFLAIR are equally reproducible; FSE yields lower volumes than CSE; fFLAIR gives similar volumes to CSE but underscores the posterior fossa. Overall clinical correlations are similar for CSE and fFLAIR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lesion contrast differences in MRI sequences in multiple sclerosis: Correlation to clinical disability

The purpose of this study was to analyze the lesion brightness (image contrast) in multiple MRI sequences in patients with relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), primary progressive MS (PPMS), and clinically isolated syndrome (CIS); and to correlate the lesion contrast with lesion volumes and neurological disability. MRI examination at 1.5 T was performed on 80 patients...

متن کامل

Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.

PURPOSE To compare fast spin-echo (FSE) and fast fluid-attenuated inversion recovery (FLAIR) sequences with conventional spin-echo (CSE) MR imaging in the quantification of the number and volume of multiple sclerosis lesions. METHODS In 30 patients with relapsing-remitting multiple sclerosis, we calculated the total number and volume of lesions detected with each of the three sequences using ...

متن کامل

T1- Thresholds in Black Holes Increase Clinical-Radiological Correlation in Multiple Sclerosis Patients

BACKGROUND Magnetic Resonance Imaging (MRI) is an established tool in diagnosing and evaluating disease activity in Multiple Sclerosis (MS). While clinical-radiological correlations are limited in general, hypointense T1 lesions (also known as Black Holes (BH)) have shown some promising results. The definition of BHs is very heterogeneous and depends on subjective visual evaluation. OBJECTIVE...

متن کامل

Quantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery.

In this study, we compared a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence to conventional spin-echo (CSE) in the evaluation of brain MRI lesion loads of seven patients with clinically definite multiple sclerosis. Interleaved CSE (3000/20, 5 mm contiguous axial slices) and fast-FLAIR (9000/150/2200, 5 mm contiguous axial slices) sequences were performed on a 1.0 T machine. Lesi...

متن کامل

Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.

PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 1998