Comparison of global cerebral blood flow measured by phase‐contrast mapping MRI with 15O‐H2O positron emission tomography

نویسندگان

  • Mark Bitsch Vestergaard
  • Ulrich Lindberg
  • Niels Jacob Aachmann‐Andersen
  • Kristian Lisbjerg
  • Søren Just Christensen
  • Peter Rasmussen
  • Niels Vidiendal Olsen
  • Ian Law
  • Henrik Bo Wiberg Larsson
  • Otto Mølby Henriksen
چکیده

PURPOSE To compare mean global cerebral blood flow (CBF) measured by phase-contrast mapping magnetic resonance imaging (PCM MRI) and by 15 O-H2 O positron emission tomography (PET) in healthy subjects. PCM MRI is increasingly being used to measure mean global CBF, but has not been validated in vivo against an accepted reference technique. MATERIALS AND METHODS Same-day measurements of CBF by 15 O-H2 O PET and subsequently by PCM MRI were performed on 22 healthy young male volunteers. Global CBF by PET was determined by applying a one-tissue compartment model with measurement of the arterial input function. Flow was measured in the internal carotid and vertebral arteries by a noncardiac triggered PCM MRI sequence at 3T. The measured flow was normalized to total brain weight determined from a volume-segmented 3D T1 -weighted anatomical MR-scan. RESULTS Mean CBF was 34.9 ± 3.4 mL/100 g/min measured by 15 O-H2 O PET and 57.0 ± 6.8 mL/100 g/min measured by PCM MRI. The measurements were highly correlated (P = 0.0008, R2  = 0.44), although values obtained by PCM MRI were higher compared to 15 O-H2 O PET (absolute and relative differences were 22.0 ± 5.2 mL/100 g/min and 63.4 ± 14.8%, respectively). CONCLUSION This study confirms the use of PCM MRI for quantification of global CBF, but also that PCM MRI systematically yields higher values relative to 15 O-H2 O PET, probably related to methodological bias. LEVEL OF EVIDENCE 3 J. Magn. Reson. Imaging 2017;45:692-699.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[15O]H2O positron emission tomography determination of cerebral blood flow during balloon test occlusion of the internal carotid artery.

PURPOSE To determine the utility of [15O]H2O positron emission tomography (PET) for the quantitative determination of cerebral blood flow in patients undergoing balloon test occlusion of the internal carotid artery. METHODS Twenty-two [15O]H2O PET cerebral blood flow studies were completed on 20 patients for whom temporary or permanent occlusion of the internal carotid artery was being consid...

متن کامل

Comparison of velocity- and acceleration-selective arterial spin labeling with [15O]H2O positron emission tomography.

In the last decade spatially nonselective arterial spin labeling (SNS-ASL) methods such as velocity-selective ASL (VS-ASL) and acceleration-selective ASL have been introduced, which label spins based on their flow velocity or acceleration rather than spatial localization. Since labeling also occurs within the imaging plane, these methods suffer less from transit delay effects than traditional A...

متن کامل

A Non-invasive Method for Quantifying Cerebral Blood Flow by Hybrid PET/MR.

While positron emission tomography (PET) with 15O-water is the gold standard for imaging cerebral blood flow (CBF), quantification requires measuring the arterial input function (AIF), which is an invasive and noisy procedure. To circumvent this problem, we propose a non-invasive PET/ magnetic resonance (MR) approach that eliminates the need to measure the AIF by using global CBF determined by ...

متن کامل

Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking After Acute Stroke in Pigs Comparison With [O]H2O Positron Emission Tomography

Background and Purpose—Early and accurate assessments of cerebral ischemia allow therapy to be tailored to individual stroke patients. We examined the feasibility of using a novel method for measuring cerebral blood flow (CBF) of ischemic tissue based on MRI after middle cerebral artery occlusion (MCAO). Moreover, the regional correlations between CBF and cerebral blood volume (CBV) were invest...

متن کامل

Validation of a simplified scatter correction method for 3D brain PET with 15O

OBJECTIVE Positron emission tomography (PET) enables quantitative measurements of various biological functions. Accuracy in data acquisition and processing schemes is a prerequisite for this. The correction of scatter is especially important when a 3D PET scanner is used. The aim of this study was to validate the use of a simplified calculation-based scatter correction method for 15O studies in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2017