Wire or coated balloon? Searching for an optimal source for intravascular brachytherapy with β emitters using 32P as an example

نویسندگان

  • J. Lehmann
  • C. R. King
چکیده

This study identifies basic dosimetric differences between two designs for intravascular brachytherapy (IVBT) in current clinical practice and ongoing trials and their clinical implications within beta emitting systems using P-32 as an example. The two designs are (i) the wire-type source, where the radioactive source material is confined to a wirelike structure within the vessel lumen, and (ii) the balloon-surface source, where the radioactive source material is distributed over a surface area (balloon-wall) which is brought in close proximity with the vessel wall. Using Monte Carlo simulations with the EGS4 code, the target coverage, the influence of centering errors, and the perturbation of the dose distribution caused by metallic stents have been compared. The radial dose fall-off in the target region was found to be steeper for balloon surface systems compared with wire systems. The inner lumen wall dose for a balloon surface source was 25% higher than that for a wirelike source (2.5 mm vessel diameter). However, the comparably shallower fall-off from wire-type systems is very sensitive to centering uncertainties. A 0.5 mm displacement, for example, will cause the dose to change by a factor of 2 at the inner vessel wall and by a factor of 1.8 at the prescription point. It is shown that the interference from metallic stents is more significant for wire-type systems than it is for balloon-surface-type systems, where double the dose variation beyond the stent at the radial prescription distance may occur. Centering uncertainties dominate the dose perturbation effects for wire-type systems. Balloon-surface-type designs show a more predictable dose distribution that features, however, a higher inner vessel surface dose. Since a direct clinical comparison of systems of both types is not likely, these findings should be considered when interpreting clinical results from treatments with either type of source and, possibly, for future source design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty

R ecent pre-clinical and clinical studies indicate that irradiation within the dose range of 15 to 30 Gy can reduce the rate of restenosis in patients who have undergone an angioplasty (Nath 1999, King 1998). Several delivery systems of intravascular brachytherapy have been developed to deliver doses within this rang with minimal normal tissue toxicity. One of the possible intravascular irradia...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Dosimetric measurements in isolated human coronary arteries: comparison of commercially available iridium(192) with strontium/yttrium(90) emitters.

BACKGROUND Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources (beta- and gamma-emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the advent...

متن کامل

Dosimetric Measurements in Isolated Human Coronary Arteries Comparison of Commercially Available Iridium With Strontium/Yttrium Emitters

Background—Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources ( and -emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the adventitia in di...

متن کامل

Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including...

متن کامل