Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries
نویسندگان
چکیده
Purpose Descemet's stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP). We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft adhesion. Case Presentation We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. Conclusions Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries.
منابع مشابه
Increased Rates of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts
PURPOSE To investigate the rates of Descemet's stripping automated endothelial keratoplasty (DSAEK) graft dislocation and failure in glaucomatous eyes, including eyes with history of trabeculectomy and/or aqueous shunts. METHODS A retrospective, case-control study on a total of 424 consecutive eyes undergoing DSAEK at an academic setting compared 96 glaucomatous eyes to a control group of 328...
متن کاملDescemet stripping automated endothelial keratoplasty in eyes with previous trabeculectomy and tube shunt procedures: intraoperative and early postoperative complications.
PURPOSE To evaluate the intraoperative and early postoperative outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with previous glaucoma filtering surgeries. METHODS A retrospective review of all DSAEK surgeries performed at one center comparing complications of DSAEK in eyes with previous glaucoma filtering procedures (study eyes) with a time-matched group ...
متن کاملModified Descemet's Stripping Automated Endothelial Keratoplasty for Congenital Hereditary Endothelial Dystrophy
A 19-year-old male with congenital hereditary endothelial dystrophy (CHED) presented with severe bilateral corneal clouding precluding any view of the intraocular structures. He underwent modified Descemet's stripping automated endothelial keratoplasty (DSAEK) technique including a suture pull-through technique to prevent lens damage. Surgery resulted in progressive clearing of the cornea and d...
متن کاملDescemet's stripping with automated endothelial keratoplasty and glaucoma.
PURPOSE OF REVIEW Descemet's stripping with automated endothelial keratoplasty (DSAEK) has recently become the preferred surgical procedure replacing penetrating keratoplasty (PKP) for corneal endothelial disorders. However, DSAEK may also be associated with postprocedure intraocular pressure elevation and secondary glaucoma, and presents unique surgical challenges in patients with preexisting ...
متن کاملNew Continuous Air Pumping Technique to Improve Clinical Outcomes of Descemet-Stripping Automated Endothelial Keratoplasty in Asian Patients with Previous Ahmed Glaucoma Valve Implantation
BACKGROUND To evaluate the outcomes of Descemet-stripping automated endothelial keratoplasty (DSAEK) with the use of continuous air pumping technique in Asian eyes with previous Ahmed glaucoma valve implantation. METHODS The DSAEK procedure was modified in that complete air retention of the anterior chamber was maintained for 10 min using continuous air pumping at 30 mm Hg. The primary outcom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2018 شماره
صفحات -
تاریخ انتشار 2018