Distal anastomotic patency of the Cardica C-PORT(R) xA system versus the hand-sewn technique: a prospective randomized controlled study in patients undergoing coronary artery bypass grafting.

نویسندگان

  • Niels J Verberkmoes
  • Sander L Wolters
  • Johannes C Post
  • Mohamed A Soliman-Hamad
  • Joost F ter Woorst
  • Eric Berreklouw
چکیده

OBJECTIVES The C-Port® Distal Anastomosis Systems (Cardica, Inc., Redwood City, CA, USA) demonstrated favourable results in feasibility trials. However, distal vein anastomoses created with the C-Port® or C-Port xA® system have never been compared with hand-sewn distal vein anastomoses. The objective of this study was to compare distal end-to-side anastomoses facilitated with the C-Port xA® System with the traditional hand-sewn method. METHODS This single-centre prospective randomized controlled study comprised 71 patients (device group n = 35, control group n = 36) who underwent primary elective coronary artery bypass grafting between June 2008 and April 2011. The primary study end-point was 12-month distal anastomotic patency, which was assessed with prospective ECG-gated 256-multislice computed tomographic coronary angiography using a step-and-shoot scanning protocol. For the primary end-point, a per-protocol analysis was used. RESULTS In the device group, four (11%) anastomoses were converted to hand-sewn anastomoses, and additional stitches to achieve haemostasis were necessary in 22 (76%) patients. There was no hospital mortality in either group. During the 12-month follow-up, a single death occurred in the Device group and was unrelated to the device. Twenty-nine patients in the device group and 32 in the control group completed 12-month CT coronary angiography. The overall patency of 160 studied distal vein graft anastomoses was 93%. Comparison of the end-to-side target anastomosis showed 12-month patencies of 86 and 88% in the device group and the control group, respectively. CONCLUSIONS According to these preliminary results and despite the limited number of patients, the use of the C-Port xA® System is safe enough to perform distal end-to-side vein graft anastomosis, with respect to 12-month end-to-side distal venous anastomotic patency. Although there are some technical challenges with this device, the incidence of complications is comparable to the traditional hand-sewn technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early patency evaluation of new distal anastomotic device in internal mammary artery grafts using computed tomography angiography.

INTRODUCTION : Traditional coronary artery bypass grafting is performed using a hand sewn technique. The C-Port xA and Flex A anastomotic stapling devices (Cardica Inc., Redwood City, CA) were cleared by the Food and Drug Administration for use in distal coronary anastomoses in November 2006 and April 2007, respectively. They provide the ability to create a compliant, consistently reproducible,...

متن کامل

Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).

OBJECTIVE During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic...

متن کامل

Prospective evaluation of patency and early experience utilizing an automated distal anastomosis device (C-port).

BACKGROUND : In November 2005, a new automated distal anastomotic device (C-Port) for coronary artery bypass grafting (CABG) was cleared by the FDA for use in the United States. This study represents a prospective evaluation of our early experience using the device with graft patency assessment determined by 64 slice multidetector row computed tomography angiography (64CT). MATERIALS AND METH...

متن کامل

Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial. Invited commentary.

BACKGROUND The PAS-Port (Cardica Inc, Redwood City, CA) is an automated system that allows for the clampless anastomosis of vein grafts to the aorta. The intent of this study was to prospectively compare one year graft patency of this system with conventional hand-sewn anastomoses in a prospective, randomized trial. METHODS A total of 99 patients undergoing elective off-pump coronary bypass s...

متن کامل

Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.

PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2013