Microtiter format for simultaneous multianalyte detection and development of a PCR-chemiluminescent enzyme immunoassay for typing human papillomavirus DNAs.

نویسندگان

  • Aldo Roda
  • Mara Mirasoli
  • Simona Venturoli
  • Monica Cricca
  • Francesca Bonvicini
  • Mario Baraldini
  • Patrizia Pasini
  • Marialuisa Zerbini
  • Monica Musiani
چکیده

BACKGROUND To allow multianalyte binding assays, we have developed a novel polystyrene microtiter plate containing 24 main wells, each divided into 7 subwells. We explored its clinical potential by developing a PCR-chemiluminescent immunoassay (PCR-CLEIA) for simultaneous detection and typing of seven high oncogenic risk human papillomavirus (HPV) DNAs in one well. METHODS Seven different oligonucleotide probes, each specific for a high-risk HPV genotype, were separately immobilized in the subwells. Subsequently, a digoxigenin-labeled consensus PCR amplification product was added to the main well. The PCR product hybridized to the immobilized probe corresponding to its genotype and was subsequently detected by use of a peroxidase-labeled anti-digoxigenin antibody and chemiluminescence imaging with an ultrasensitive charge-coupled device camera. Results obtained for 50 cytologic samples were compared with those obtained with a conventional colorimetric PCR-ELISA. RESULTS The method was specific and allowed detection of 50 genome copies of HPV 16, 18, 33, and 58, and 100 genome copies of HPV 31, 35, and 45. Intra- and interassay CVs for the method were 5.6% and 7.9%, respectively. All results obtained for clinical samples were confirmed by the conventional PCR-ELISA. CONCLUSIONS PCR-CLEIA allows rapid, single-tube simultaneous detection and typing of seven high-risk HPV DNAs with small reagent volumes. The principle appears applicable to the development of other single-tube panels of tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High sensitivity multianalyte immunoassay using covalent DNA-labeled antibodies and polymerase chain reaction.

A multianalyte immunoassay for simultaneous detection of three analytes (hTSH, hCG and beta-Gal) has been demonstrated using DNA-labeled antibodies and polymerase chain reaction (PCR) for amplification of assay response. The labeled antibodies were prepared by covalently coupling uniquely designed DNA oligonucleotides to each of the analyte-specific monoclonal antibodies. Each of the DNA oligon...

متن کامل

Multiplex Reverse Transcriptase-PCR Assay for Typing and Subtyping of Influenza A (H5 & H9) Virus in Iran

Avian influenza virus (AIV) infection is a major cause of bird or human mortality and morbidity, therefore the rapid identification of the virus is of important clinical and epidemiological implication. Methods: A multiplex Reverse Transcriptase PCR (RT-PCR) was optimized for the detection of influenza A virus and the H5 and H9 subtypes. The influenza type A specific primers were directed to t...

متن کامل

Multiplex tumor marker detection with new chemiluminescent immunoassay based on silica colloidal crystal beads.

A new multiplex chemiluminescent immunoassay (CLIA) based on silica colloidal crystal beads (SCCBs) was developed for tumor marker detection. As the code is the characteristic reflection peak originating from the stop-band of colloid crystal, they avoid photobleaching, the potential interference of encoding fluorescence with analyte-detection fluorescence and chemical instability. Meanwhile our...

متن کامل

Development and evaluation of a colorimetric PCR system for the detection and typing of human papillomaviruses.

In developing countries, the introduction of human papillomaviruses (HPV) DNA testing as an adjunct to cytological screening programs has been delayed due to the lack of high performance and cost effective diagnostic nucleic acid methods. In this study we report the development and evaluation of the L1HPVPCR, a PCR-based method for the detection and typing of five of the most prevalent high-ris...

متن کامل

Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers.

A novel flow-through immunosensing system for performing a multianalyte chemiluminescent determination in a single run was designed. A new analytical strategy of substrate zone-resolved technique was proposed. Using carcinoma antigen 125 (CA 125) and carcinoembryonic antigen (CEA) as model analytes, the capture antibodies for CA 125 and CEA were immobilized on an UltraBind aldehyde-activated me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 2002