Slow late myocardial clearance of thallium: a characteristic phenomenon in coronary artery disease.

نویسندگان

  • J Sklar
  • D Kirch
  • T Johnson
  • B Hasegawa
  • S Peck
  • P Steele
چکیده

We extended the quantitative seven-pinhole method to follow the dynamics of thallium redistribution after exercise. We observed a pattern of slow late thallium clearance that appears to be characteristic of myocardium supplied by obstructed coronary arteries. In 28 subjects, quantitative thallium scintigrams (seven-pinhole tomography, circumferential count profiles) and blood samples for thallium concentration were taken immediately, 2 hours and 4 hours after maximal treadmill exercise. Twenty subjects had coronary artery disease (CAD) and eight were normal. The rate of thallium clearance from the blood (TCB) was compared with the rate of thallium clearance from each segmental region of myocardium (TCM, derived by ratioing corresponding segments of the absolute circumferential count profiles) between the 2- and 4-hour images. In seven of the eight normal subjects, TCM exceeded TCB in all regions of all images (specificity 88%). Seventeen of the 20 CAD patients had at least one region where TCM was less than TCB (sensitivity 85%). Of the 13 patients with multivessel CAD, 11 had multiple regions with TCM less than TCB. Using this criterion, we detected 31 of 39 obstructed coronary arteries. Of the 37 regions that were abnormal by this analysis, 30 corresponded to obstructed coronary arteries. In contrast, while conventional circumferential count profile analysis also was abnormal in 17 of the 20 CAD patients, it diagnosed multivessel CAD in only five of the 13 patients that had it. These results show that slow late thallium clearance from myocardium is characteristic of regions of myocardium supplied by diseased coronary arteries and that observation of this phenomenon may improve diagnostic sensitivity for the presence of multivessel CAD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THALLIUM REDISTRIBUTION AFTER EXERCISE IN CAD / Sklar

coronary artery disease Slow late myocardial clearance of thallium: a characteristic phenomenon in

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

THALLIUM-201 STRESS TEST IN 156 PATIENTS WITH SUSPECTED CORONARY ARTERY DISEASE

Currently, myocardial TI-201 scintigraphy is most often performed in conjunction with exercise stress testing in patients with suspected or known CAD. Stress thallium tests were performed for 156 patients with and without old myocardial infarctions complaining of chest pain. All of them underwent contrast coronary angiography. Perfusion defects were mostly manifested as reversible defects ...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Tc-99m-MIBI in evaluation of myocardial perfusion [Persian]

Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 65 7  شماره 

صفحات  -

تاریخ انتشار 1982