What Next After Failed Septal Ventricular Tachycardia Ablation?

نویسندگان

  • Laurent Roten
  • Nicolas Derval
  • Patrizio Pascale
  • Pierre Jais
  • Pierre Coste
  • Frederic Sacher
چکیده

Ablation of ventricular tachycardia (VT) by conventional radiofrequency ablation can be impossible if the ventricular wall at the targeted ablation site is very thick, as for example the ventricular septum. We present a case of a patient with incessant, non-sustained slow VT originating from the septal part of the lower outflow tracts. Radiofrequency catheter ablation from both ventricles as well as from the anterior cardiac vein were not successful. Both high power radiofrequency ablation and bipolar radiofrequency ablation neither were successfull. Finally, ethanol ablation of the first septal perforator successfully terminated arrhythmia. We discuss the possibilities to overcome failed conventional radiofrequency VT ablation of a septal focus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency catheter ablation of atriofascicular and nodoventricular Mahaim tracts.

BACKGROUND Several mechanisms have been proposed to explain the pathogenesis of tachycardia in patients with Mahaim tracts. The tachycardia may involve antegrade conduction over an atriofascicular pathway with decremental properties or a nodofascicular pathway. METHODS AND RESULTS We report six patients with recurrent episodes of preexcited tachycardia with findings consistent with "Mahaim tr...

متن کامل

Retrograde Coronary Venous Ethanol Infusion for Ablation of Refractory Ventricular Tachycardia.

BACKGROUND Radiofrequency ablation (RFA) of ventricular tachycardia (VT) can fail because of inaccessibility to the VT substrate. Transarterial coronary ethanol ablation can be effective but entails arterial instrumentation risk. We hypothesized that retrograde coronary venous ethanol ablation can be an alternative bail-out approach to failed VT RFA. METHODS AND RESULTS Out of 334 consecutive...

متن کامل

A case of incessant VT from an intramural septal focus: Ethanol or bipolar ablation?

Introduction Substrate-based radiofrequency (RF) ablation of scar-related ventricular tachycardia (VT) has become standard practice, often in addition to an intracardiac cardioverter-defibrillator. VT procedures without identified substrate are particularly challenging cases, especially when VT is noninducible. An intramural focus is often challenging to ablate using conventional RF ablation, a...

متن کامل

Simultaneous biventricular noncontact mapping and ablation of septal ventricular tachycardia in a chronic ovine infarct model.

BACKGROUND We assessed a novel simultaneous biventricular mapping and ablation approach for septal ventricular tachycardia (VT) in a chronic ovine infarct model. METHODS AND RESULTS In 8 sheep with inducible VT, mapping and ablation were performed 9+/-3 months after percutaneously induced myocardial infarction, with left ventricular ejection fraction 23+/-8%. Scar was identified by EnSite Dyn...

متن کامل

Successful catheter ablation of ventricular tachycardia in a patient with congenitally corrected transposition of great arteries after double switch operation

Ventricular tachycardia (VT) may cause sudden death late after repair of congenital heart disease. Radiofrequency catheter ablation (CA) of VT can be effective but may be hampered by hypertrophied myocardium or prosthetic material. A 33-year-old man with congenitally corrected transposition of the great arteries (ccTGA) had undergone a double switch operation (DSO) with the combined Mustard and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -