An Automatic Control System of the Blood Pressure of Patients Under Surgical Operation
نویسندگان
چکیده
We developed an automatic blood pressure control system to maintain the blood pressure of patients at a substantially low level during a surgical operation. The developed system discharges two functions, continuous feedback control of the mean arterial pressure (MAP) by a state-predictive servo controller and risk control based on the inference by fuzzy-like logics and rules using measured data. Twenty-eight clinical applications were made beginning in November 1995, and the effects of the automatic blood pressure control on the operation time and on bleeding were assessed affirmatively by means of Wilcoxon testing. This paper essentially reports the engineering details of the control system.
منابع مشابه
بررسی و مقایسه تاثیر دیازپام وریدی با میدازولام وریدی به عنوان پیش داروی بیهوشی بر چگونگی اشباع اکسیژن خون شریانی قبل از شروع عمل جراحی در بیماران ریسک یک تحت بیهوشی عمومی در اطاق عمل یکی از ...
This research, which is semi- experimental is focused on the influence and comparison intravenous diazepam with intravenous midazolam as premedication in anesthesia on the saturation arterial blood oxygen before surgical operation, "pan patients who are in risk one under general anesthesia in the operating rooms of the hospitals affiliated to Iran University of Medical Sciences and Heal...
متن کاملبررسی میزان خونریزی در اعمال جراحی فیوژن خلفی مهره های کمری با پیش داروی کلونیدین خوراک
Background: Blood loss in spine surgery is an important issue, even though it has been understudied compared to hip and knee arthroplasty surgery. In this study we have evaluated the effect of oral clonidine as premedication on blood loss in lumbar spine fusion surgery under propofol and remifentanil anesthesia.Materials and Methods: In this prospective double-blinded randomized clinical trial,...
متن کاملمیزان بروز وعوامل زمینه ساز زخم های فشاری بعداز اعمال جراحی قلب باز
Background : This study was conducted to assess incidence rate sores after cardiac surgery during hospitalization and its relevant factors, also discussed differences between sore and burn as a result of unstandard connections of electrocautery system in operating room. Surgical patients because of risk factors that exist in operating room, have more potential to develop pressure sore than ...
متن کاملStudying Changes of the Effective Radius in Blood Vessels after Exposure of Lower Extremities to Periodical Mechanical Vibrations
Background: Previous studies demonstrated a health improving effect in patients underwent an automatic vibratory massage taking 10 minutes. One of reasons that may explain a healing effect of the automatic massage is a stimulated increase in both blood circulation through vascular system and effective size of blood vessels. Objective: This paper aims to quantify a contribution of the auto...
متن کاملEffect of Passive Movements of Lower Extremity on Hemodynamic Parameters of the Patients under Ventilator
Aims: The present study was conducted with the aim of determining the effect of passive movements on hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse, and pulse pressure of patients under ventilation. Materials & Method: In this controlled clinical trial, 64 patients under ventilation in Kohgiluyeh and Boyer-Ahmad University of ...
متن کامل