Pharmacodynamic and efficacy profile of TGN 255, a novel direct thrombin inhibitor, in canine cardiopulmonary bypass and simulated mitral valve repair.
نویسندگان
چکیده
Heparin-induced thrombocytopenia can be a life-threatening sequel to conventional use of unfractionated heparin in cardiopulmonary bypass (CPB). This study evaluated the pharmacokinetic/pharmacodynamic (PK/PD) and efficacy profile of a novel direct thrombin inhibitor, TGN 255, during cardiac surgery in dogs. Point-of-care coagulation monitoring was also compared against the plasma concentrations of TRI 50c, the active metabolite of TGN 255. The study was conducted in three phases using 10 animals: phase 1 was a dose-ranging study in conscious animals (n = 6), phase 2 was a similar but terminal dose-ranging study in dogs undergoing CPB (n = 6), and phase 3 was with animals undergoing simulated mitral valve repair (terminal) using optimal TGN 255 dose regimens derived from phases I and II (n = 4). During the study, PD markers and drug plasma levels were determined. In addition, determinations of hematologic markers and blood loss were undertaken. Phase 1 studies showed that a high-dose regimen of a 5-mg/kg bolus and infusion of 20 mg/kg/h elevated PD markers in conscious animals, at which time there were no measured effects on platelet or red blood cell counts, and the mean plasma concentration of TRI 50C was 20.6 microg/mL. In the phase 2 CPB dose-ranging study, this dosing regimen significantly elevated all the PD markers and produced hemorrhagic and paradoxical thrombogenic effects. In the phase 3 surgical study, a lower TGN 255 dose regimen of a 2.5-mg/kg bolus plus 10 mg/kg/h produced anticoagulation, elevated PD markers, and produced minimal post-operative blood loss in the animals. Plasma levels of TRI 50C trended well with the conventional point-of-care coagulation monitoring. TGN 255 provided effective anticoagulation in a canine CPB procedure, enabling successful completion with minimal blood loss. These findings support further evaluation of TGN 255 as an anticoagulant for CPB.
منابع مشابه
Beating heart mitral valve repair for a patient with previous coronary bypass: a case report and review of the literature
Mitral valve reoperation, through a median sternotomy, for a patient with patent coronary bypass grafts is technically challenging and carries higher postoperative morbidity and mortality than a primary operation. We present a case of mitral valve repair using a beating heart technique under normothermic cardiopulmonary bypass that was performed 3 years after a coronary artery bypass operation....
متن کاملTranscatheter Mitral Valve Implantation
T he rationale for the development of a transcatheter mitral valve implantation (tMVI) procedure, either percutaneous or via minimally invasive surgery (MIS), arose from consideration of several key surgical concepts. First, mitral valve replacement is the most effective modality and the gold standard procedure for reliably reducing mitral regurgitation (MR). The efficacy and risks of mitral va...
متن کاملAnticoagulant monitoring techniques in a heparin-induced thrombocytopenia patient undergoing cardiopulmonary bypass using bivalirudin anticoagulant.
Heparin is widely used as the anticoagulant of choice for cardiopulmonary bypass. However, some patients exposed to heparin therapies develop heparin-induced thrombocytopenia (HIT). Severe complications of HIT-induced thrombosis may lead to end-organ dysfunction and death. Bivalirudin, a hirudin analog, is an alternative anticoagulant that may be used in the patient with HIT without inducing th...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملReal-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair
BACKGROUND Artificial chordae replacement is an effective technique for mitral valve repair, however, it is difficult to accurately determine the length of artificial chordae. This study aimed to assess the reliability and accuracy of real-time three-dimensional transesophageal echocardiography (TEE) to predict the length of artificial chordae preoperatively. METHODS From December 2008 to Dec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2008