Spectrophotometric determination of biologically active thiols with eosin, silver(I) and adenine.
نویسندگان
چکیده
A simple and highly sensitive spectrophotometric method for the determination of biologically active thiols based on the fading of eosin-silver(I)-adenine ternary complex was established. In the determination of 6-mercaptopurine (MP), Beer's law was obeyed in the range 0.02-0.30 microg ml(-1), with an effective molar absorptivity at 562 nm and the relative standard deviation being 3.5 x 10(5) dm3 mol(-1) cm(-1) and 0.72% (n = 5). Analytical data for various biologically active thiols were determined with the proposed method. This method is about 5-10 times more sensitive than the conventional spectrophotometric methods. A compound having a disulfide bond (-S-S-), such as cystine, could also be determined by the conversion of disulfides to free thiols with the sulfite ion. The procedure was successfully applied to assays of various biologically active thiols in actual medicines.
منابع مشابه
SPECTROPHOTOMETRIC REACTION RATE METHOD FOR THE DETERMINATION OF SLWR BASED ON ITS CATALYTIC EFFEICT ON THE OXIDATION OF GLLOCYANW BY PER0XYDISULPTE
A sensitive and selective procedure was developed for the spectrophotometric determination of silver by its catalytic effect on the oxidation of gallocyanine by peroxydisulphate in acidic media at 540 nm. Silver can be determined in the range of 0.001-0.500 µg/ml with a limit of detection of 0.0005 µg/ml, by a fixed-time method of 4.0 min from initiation of the reaction, The relative standa...
متن کاملAutomated Determination of Pharmaceutically and Biologically Active Thiols by Sequential Injection Analysis: A Review
The present review article presents and discusses automated sequential injection (SI) based methods for the determination of pharmaceutically and biologically important thiols, namely cysteine, N-acetylcysteine, penicillamine, glutathione and captopril. The review intends to cover a range of ten years of published research on this topic (2000 – 2009). The methods are classified according to the...
متن کاملCatalytic Kinetic Determination of Silver through its Catalytic Effect on Congo Red-Peroxodisulphate Reaction
A kinetic-spectrophotometric procedure is reported for determination of trace amounts of Ag(I). This method is based on catalytic effect of silver ion on the oxidation of congo red by potassium peroxodisulphate at pH=3.4 and 30 oC in the presence of 1,10-phenanthroline as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance ...
متن کاملDetermination of coenzyme A (CoASH) in the presence of different thiols by using flow-injection with a UV/Vis spectrophotometric detector and potentiometric determination of CoASH using an iodide ISE.
Coenzyme A (CoA or CoASH) is one of the most important biologically active compounds, and for this reason a reliable, fast and simple determination of CoASH is needed. Here we are described a simple and fast way of determinating CoASH using potentiometric flow-injection analysis and spectrophotometric kinetic determination. The described methods are suitable for use over a wide concentration ra...
متن کاملDesign and Evaluation and Synthesis a Starch-Capped Silver NanoParticles Sensor and Determination trace Sulfacetamide Drug in the Presence Sodium borohydride in Blood and Urine Samples with Kinetic Spectrophotometric Method
A new Kinetic Spectrophotometic method for the Determination of trace amount Sulfacetamide Drug into real samples has been described based with silver nanoparticles starch-capped sensor, by sodium borohydride. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 347.5 nm. 1.0×10-2 molL-1 silver nanoparticles starch-capped sensor, 2.0×10-3 mol L-1 sodium...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2002