Concordance, variance, and outliers in 4 contemporary cardiac troponin assays: implications for harmonization.

نویسندگان

  • Jacobus P J Ungerer
  • Louise Marquart
  • Peter K O'Rourke
  • Urs Wilgen
  • Carel J Pretorius
چکیده

BACKGROUND Data to standardize and harmonize the differences between cardiac troponin assays are needed to support their universal status in diagnosis of myocardial infarction. We characterized the variation between methods, the comparability of the 99th-percentile cutoff thresholds, and the occurrence of outliers in 4 cardiac troponin assays. METHODS Cardiac troponin was measured in duplicate in 2358 patient samples on 4 platforms: Abbott Architect i2000SR, Beckman Coulter Access2, Roche Cobas e601, and Siemens ADVIA Centaur XP. RESULTS The observed total variances between the 3 cardiac troponin I (cTnI) methods and between the cTnI and cardiac troponin T (cTnT) methods were larger than expected from the analytical imprecision (3.0%-3.7%). The between-method variations of 26% between cTnI assays and 127% between cTnI and cTnT assays were the dominant contributors to total variances. The misclassification of results according to the 99th percentile was 3%-4% between cTnI assays and 15%-17% between cTnI and cTnT. The Roche cTnT assay identified 49% more samples as positive than the Abbott cTnI. Outliers between methods were detected in 1 patient (0.06%) with Abbott, 8 (0.45%) with Beckman Coulter, 10 (0.56%) with Roche, and 3 (0.17%) with Siemens. CONCLUSIONS The universal definition of myocardial infarction should not depend on the choice of analyte or analyzer, and the between- and within-method differences described here need to be considered in the application of cardiac troponin in this respect. The variation between methods that cannot be explained by analytical imprecision and the discordant classification of results according to the respective 99th percentiles should be addressed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outliers as a cause of false cardiac troponin results: investigating the robustness of 4 contemporary assays.

BACKGROUND It is important that cardiac troponin be measured accurately with a robust method to limit false results with potentially adverse clinical outcomes. In this study, we characterized the robustness of 4 analytical platforms by measuring the outlier rate between duplicate results. METHODS We measured cardiac troponin concurrently in duplicate with 4 analyzers on 2391 samples. The outl...

متن کامل

Toward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays.

BACKGROUND Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS Two troponin ...

متن کامل

Transitioning high sensitivity cardiac troponin I (hs-cTnI) into routine diagnostic use: More than just a sensitivity issue

OBJECTIVES High sensitivity cardiac troponin T and I (hs-cTnT and hs-cTnI) assays show analytical, diagnostic and prognostic improvement over contemporary sensitive cTn assays. However, given the importance of troponin in the diagnosis of myocardial infarction, implementing this test requires rigorous analytical and clinical verification across the total testing pathway. This was the aim of thi...

متن کامل

Edging closer to early optimal patient management with high-sensitivity cardiac troponin assay.

These are exciting times in the evolution of cardiac biomarkers. In the past 12 years, we have witnessed the transition from creatine kinase-MB to cardiac troponin I (cTnI) and T (cTnT) as the standard biomarkers to aid in the diagnosis of acute myocardial infarction (MI). This is evidenced by the overwhelming endorsement through recommendations from laboratory medicine,1 cardiology,2 and emerg...

متن کامل

Determination of 19 cardiac troponin I and T assay 99th percentile values from a common presumably healthy population.

BACKGROUND Between-assay comparability of 99th percentiles for cardiac troponin concentrations has not been assessed systematically in a single population for a large number of assays. METHODS We determined 99th percentiles for 19 cardiac troponin assays in heparin plasma samples from a population of 272 and 252 presumably healthy males and females, respectively. The assays evaluated included...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2012