Changes in corneal biomechanics following different keratoplasty techniques

نویسندگان

  • Mohamed Hosny
  • Mohamed Abdel Moneim Hassaballa
  • Ahmed Shalaby
چکیده

PURPOSE To evaluate corneal biomechanics with the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Depew, NY) after penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK). SUBJECTS AND METHODS Sixty-three eyes of 63 patients were included in this prospective comparative study. Patients were divided into 3 groups: the first included 21 eyes of normal subjects (control group); the second included 21 eyes with PK; the third included 21 eyes with DALK. ORA was performed 2 months postoperatively for all patients. RESULTS Both mean corneal hysteresis (CH) and mean corneal resistance factor (CRF) were significantly lower in the PK group than both the DALK group and matched controls. No statistically significant difference was found between mean CH and mean CRF between the DALK group and matched controls CONCLUSION Corneas after PK have weaker biomechanical properties than normal corneas. DALK preserves the biomechanical strength of the corneas to almost normal values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Graft Biomechanics Following Three Corneal Transplantation Techniques

PURPOSE To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 e...

متن کامل

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

Quantification of Collagen Ultrastructure after Penetrating Keratoplasty – Implications for Corneal Biomechanics

PURPOSE To quantify long-term changes in stromal collagen ultrastructure following penetrating keratoplasty (PK), and evaluate their possible implications for corneal biomechanics. METHODS A pair of 16 mm post-mortem corneo-scleral buttons was obtained from a patient receiving bilateral penetrating keratoplasty 12 (left)/28 (right) years previously. Small-angle x-ray scattering quantified col...

متن کامل

Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any...

متن کامل

Corneal iron ring after conductive keratoplasty.

PURPOSE To report formation of corneal iron ring deposits after conductive keratoplasty. DESIGN Observational case report. METHODS Case report. RESULTS A 54-year-old woman underwent conductive keratoplasty for hyperopia. One year after conductive keratoplasty, iron ring pattern pigmentation was detected at the corneal epithelium of both eyes. CONCLUSIONS This is the first report of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011